Gas Pressure

Correct gas pressure is essential for efficient and safe
operation of the GF 300 DV gas stove. It is important
that the correct pressure is established at the time of
the installation. Proper gas pressure provides a
consistent flow of gas to the appliance and is instru-
mental in checking for gas leaks.

Pressure Test: Attach a manometer to the appro-

priate test point on the valve. See fig. 29. The gauge
connections are located on the front of the valve
under the On/Off/Pilot- knob. Gauge connections are
identified by:

E - for Inlet or Supply Pressure (the amount of

gas coming to the valve.)

A - for Manifold Pressure (the amount of gas that

is coming out of the valve to the burner.)

ALWAYS TEST PRESSURES WITH VALVE CONTROL

KNOB SET ON HIGH.

High Altitude Adjustment

Installations located at altitudes from 2000 - 4500 ft.

(610 m -1370 m) DO NOT require adjustment for alti-
tude. DO NOT DERATE THIS APPLIANCE FOR ALTITUDE.

INLET GAS PRESSURES

(inches water column)

MIN MAX

NATURAL GAS 5.0

7.0

PROPANE

12.0

14.9

The appliance and its appliance main gas valve

must be disconnected from the gas supply piping
system during any pressure testing on that system
at test pressures in excess of 1/2 psig (3.5 kPa).

The appliance must be isolated from the gas

supply line by closing its individual manual gas
shut-off valve (gas cock) during any pressure
testing of the gas supply piping system that is
equal to or exceeds pressures of 1/2 psig (3.5 kPa).

MANIFOLD PRESSURES

(inches water column)

MIN MAX

NATURAL GAS 1.2

3.8

PROPANE

2.9

11.0

Figure 29. Pressure test points.

Leak test:

1. Mix a 50-50 solution of water and dish

soap.

2. Light appliance- see lighting instructions

on the inside back cover of this manual
or on the stove’s rating plate.

3. Brush or spray all joints and connections

with the soapy water solution.

4. If bubbles appear at any connection or

seam or a gas odor is detected, immedi-
ately turn gas control knob to the OFF
position.

5. Tighten or reconnect the leaking joint

and retest for any gas leaks.