Overview – Samsung SCC-C4255P User Manual

Page 10

Advertising
background image

overview

10_ overview

1. ALARM OUT
Alarm out jack for motion detection. (Open Collector, On Gnd)
2. GND
Grounding jack.
3. TRIGGER IN (SCC-C4255P/C4355P)
Displays the current still image when it receives the Trigger signal. (Normal
Open Type)
4.5.6 FOCUS, COM, ZOOM
This port is used for ZOOM/FOCUS, MENU CONTROL, HOME

RETURN, and ONEAF by using an external controller.

Depending on the input condition, 4 modes, A, B, C, and D are

available. (SPECIAL - CTRL TYPE)

(Operation Voltage Range : +3V~+13V, -3V~-13V)

1) When the voltage is supplied to either ZOOM or FOCUS port

Function

*1

Code

Tele(Up)

Wide(Down)

Near(Left)

Far(Right)

ZOOM Port

FOCUS Port

A

-6V

+6V

-6V

+6V

B

-6V

+6V

+6V

-6V

C

+6V

-6V

-6V

+6V

D

+6V

-6V

+6V

-6V

*1: During MENU OFF, controls ZOOM/FOCUS and during MENU ON,

changes the direction, Up/Down/Left/Right SETUP switch.

2) When the voltage is supplied to both ports

Function

Code

ENTER/AF *2

HOME RETURN *3

ZOOM Port

FOCUS Port

ZOOM Port

FOCUS Port

A

-6V

-6V

+6V

+6V

B

-6V

+6V

+6V

-6V

C

+6V

-6V

-6V

+6V

D

+6V

+6V

-6V

-6V