Samsung SCC-C4255P User Manual

Page 11

Advertising
background image

English

_11

English

* 2 : For short voltage supply during MENU OFF, executes ONEAF and for

more than 2 second

* 3 : For more than 2 second long voltage supply, moves to the PRESET

0(HOME) position.

7. 5V OUT
Power supply jack for RS-485 JIG. Use within typical DC +5V 100mA.
8. DAY/NIGHT IN
This is a function to receive the external DAY/NIGHT signal from the
sensor(option) and convert the signal into BW.
9. RS-485 DATA-

Jack for connection to RS-485 DATA- signal line.
10. RS-485 DATA+

Jack for connection to RS-485 DATA+ signal line.

SETUP Switch

This switch is used to set the function or property. When this switch is pressed
for at least 2 seconds, the MAIN MENU appears.



(Left/Right) : By pressing this switch left or right, you can move left or right

on the menu or change the displayed value.



(Up/Down) : By pressing this switch up or down, you can move up or down on

the menu.

: When you press this switch in the menu, the selected function is confirmed.

To enter a submenu, press this button.

video OUT Port

This is connected to the Video Input Port of the monitor and it outputs the
Video signals.

GND

This is a grounding port.

Power Connection Port

This is connected to the Power cable.

Power Display LED

When the power is normally connected, the red LED lights.

EU ENGLISH.indd 11

2009-9-10 13:53:47

Advertising