Stewart Filmscreen Corp LCD Front Projector User Manual

Page 10

Advertising
background image

8

Stewart Filmscreen Corporation

Figure 5: Low voltage 3-button switch wiring

3-button Momentary

Switches

Screen

Door

8 Conductor Hook-up Cable - 18ga Minimum Category 5
recommended
(NOT Supplied)

STOP-Yellow

COMMON-White

DOWN-Black

4 Conductor Hook-up Cable—20-24ga Recommended

Category 5 Typically Used (NOT Supplied)

STOP-Yellow

COMMON-White

UP-Red

DOWN-Black

UP-Red

NEUTRAL-White

GREEN-Ground

HOT-Black

NEUTRAL-White

GREEN-Ground

HOT-Black

Mask

Note: The cable wires can be split with extra length
added so that you can move the control units to a
location at a distance from the screen case.

Advertising