EF4100 Overall Dimensions

Figure 2

Provide ade qua te clearan ce s aroun d air openings into the

com bustion chamber and adequate accessibility clearance for
servicing and prope r operation. Never obstruct the front
opening of the hea ter.

The heater may be installed as a free-stan ding unit m oun t-

ed on a noncombustible protective floor pad or he arth, o r it
may be m oun ted into an existing U. L. approved wood stove
chimney using a Hearth Extension (p/n 11099). Non-combu-
stib le floor protection is required and must be used when
placin g th e hea ter on any com bu stib le m ate rial.

The pellet heater m ust b e operated with a power source

and will not o pe rate u sin g natural draft. If there is a power
failure the heater will shut down. If the 12 volt back-up system
is installed, th e hea ter will auto m atic ally switc h to 12 volt
power. An optional backup battery is available for the un it
which lasts approximately 48 hrs on high and 72 hrs on low.
A bigger battery may be purch ased if desired for longer
durations.

The EasyFire Pellet Heater has been listed by OM NI-Test

Laboratories, Inc. to ASTM, U.L.,and EPA Standards.

CAUTION: Do not connect this unit to a chimney flue serving
another appliance.

Use only listed Type "L" pellet vent or stainless liner and

com pon ents for installation. Failure to us e listed com pon ents
will void your warranty. See pipe manufacturer instructions for
installation instructions.

OU TS IDE CO M BU ST ION AIR IS M AND ATO RY IN
MO BILE OR MO DULAR HOM E INSTALLATIONS.
SEE
SECTION ON OUTSIDE AIR INSTALLATION.

C A U T IO N : D O N O T C O N NE C T TO AN Y AI R
DISTRIBUTION DUCT O R SYSTEM .

INSTALLATION INSTRUCTIONS

Check with local building officials for specific code
requirements.

A lis ted , type "L" Pe llet V en t Pip e or Stain les s Liner is
MANDATORY on all installations.

WARNING: In sta lla tio n o f a M ob ile Atta ch m en t H om e
Kit P/N 1041 2 an d ou tside c om bu stion air is ma nd atory
in mobile or modular home installations
although it may
also be u sed in all reside ntial application s.

An outs ide air inlet MU ST be provided for

com bu stion and ven tilation air. The air inlet must
rem ain unrestricte d w hile unit is in use. O uts ide air
conne ction is located in the rear of the heater (Figure 1).

NOTE: Vent Pipes’ inner diameters may vary.
For Vent Pipes Ø3.00" or smaller, use SPI Exhaust Vent
Adapter p/n 11076.

This adapter is used on Selkirk Metalbestos™ and other
Ø2.950" I.D. Pellet Vent Pipes.

Use conduit pipe or metal flex pipe and/or fittings to make
the air intake hook-up.

Also, the struc tural inte grity of th e m ob ile hom e floo r,
walls and ceiling/roof must be maintained
.

1. Clean and inspect the fireplace and its chim ney for any

structural defect that may cause any future problems.
Secure gas piping that is installed with a cap and verify
there are no leaks. Seal ash dump or an y other acc ess to
the firebox area. Fix the damper in an open position or
remove it as required for vent pipe installation.

2. Verify the req uired hea rth an d side and clear anc es to

mantels (fig. 2 & 3).