Product information CP 343–1
C79000–Z8964–C038–05

STOP–LED

(yellow)

CP operating mode

SF–LED

(red)

RUN–LED

(green)

Module fault / system error

Legend:

lit

off

flashing

Note

Read the explanations of the operating modes in the NCM S7 for
Industrial Ethernet manual /8/.

Controlling the Operating Mode

There are three ways in which you can control the mode of the CP 343-1, as
follows:

S

Mode selector

S

From a PG/PC. You can also control the modes using the configuration
software in STEP 7, as follows .

– NCM S7, Diagnostics for Industrial Ethernet (see /8/);

– SIMATIC Manager\CP343-1\PLC\Operating Mode

Mode Selector

With the mode selector, you can set the following modes:

S

Switch from STOP to RUN:
In the RUN mode, all communication services are available.

The CP modes can only be controlled using NCM S7 or the SIMATIC
Manager when the selector is set to RUN.

S

Switch from RUN to STOP:
The CP changes to the STOP mode.

In the STOP mode, only the configuration and diagnostic functions are
available on the CP 343-1.