CABLE SELECTION

Item

Cable Type

1

DC 12V Product Power

€

This

product

Belden #9409, 18 AWG 2 Conductor, Unshielded

2

Reader (Power and Data) External
Reader

€

This product

Belden #9512, 22 AWG 4 Conductor, Shielded

Belden #9514, 22 AWG 8 Conductor, Shielded

3

Door Contact Sensor

Exit Button

Sensor Input

Input

€

This product

Belden #9512, 22 AWG 4 Conductor, Shielded

Belden #9514, 22 AWG 8 Conductor, Shielded

4

Door Lock

Alarm Device

Lock (Alarm)

€

This product

Belden #9409, 18AWG 2 Conductor, Unshielded

5

RS-232 Cable

Converter

€

Host P.C.

Belden #9829, 24 AWG 2-twisted pair, Shielded

6

RS-485 Cable

SSA-P102

€

SSA-P102

SSA-P102

€

Converter

Belden #9829, 24 AWG 2-twisted pair, Shielded

RS-422 Cable

SSA-P102

€

SSA-P102

SSA-P102

€

Converter

Belden #9830, 24 AWG 3-twisted pair, Shielded

The cables should be thick enough to allow the maximum current consumed by the reader.