SAFETY INSTRUCTIONS

2

WARNING:

1.
2.
3.
4.

5.

6.
7.

8.

9.

10.

11.

12.

13.
14.
15.
16.
17.
18.
19.
20.

21.
22.
23.
24.

Read all warnings posted on the Elite Inversion System.
The Elite Inversion System should only be used after a thorough review of the Owner's Manual.
We recommend that two people be available for assembly of this product.
Do not use the Elite Inversion System alone. Always have a helper available in case assistance is needed in recovering
from the decline position.
Make sure that the Pivot Arms are assembled using the same hole on both Pivot Arms. Pay close attention to Steps 3 and
4 on page 7.
Make sure that the Pivot Arms are always secured to the pegs on the Main Frame with the Quick Releases.
Make sure that the Pad Tubes are assembled with the ends pointed down as directed in STEP 9 on page 9. The ends must
be pointed downward to properly secure the users feet in place during inversion. Improper assembly will allow the users
feet to come loose allowing the user to fall from the inversion table.
Do not use the Elite Inversion System until you have verified your height setting. Failure to use the proper height setting
can result in difficulty recovering from the decline position. See HEIGHT ADJUSTMENT instructions on page 11.
Always make sure that your feet are properly secured in the heel Holder mechanism when using the Elite Inversion
System.
Insert the Ball Pins in the lowest adjustment holes in the Angle Adjustment Tubes to restrict the movement of the inversion
bed to the least amount of inversion angle. Use this setting until you have verified your height setting and become familiar
with the Elite Inversion System.
Both Pivot Arms must always be adjusted to the same hole.
You must understand how to recover from the fully inverted position before using the fully inverted position. Read the
RECOVERY FROM LOCKED POSITION section at the bottom of page 14 BEFORE using the fully inverted position.
Always insert the Ball Pins into the same adjustment hole on both sides of the Elite Inversion System.
Do not allow children to use or play on the Elite Inversion System.
Keep small children and pets away from the Elite Inversion System at all times.
The Elite Inversion System should not be used by persons weighing more than 300 lbs.
The Elite Inversion System should not be used by persons over 6 feet 6 inches tall.
It is recommended that you place this exercise equipment on an equipment mat.
Use the Elite Inversion System only on a level surface.
Wear appropriate clothing when exercising; do not wear loose clothing that could become caught in the Elite Inversion
System.
Be sure that there is enough room for the bed to rotate completely.
Use the Elite Inversion System only as described in the manual.
The safety level of the Elite Inversion System can be maintained only if it is examined regularly for damage and wear.
This equipment is for home use only. It is not for commercial use.

Maintenance Instructions

15

Product Parts Drawing

16

Parts List

17

Warranty

19

Notes

20

Fax/Mail Ordering Form

22

Safety Instructions

2

Before You Begin

4

Hardware Identification Chart

5

Assembly Instructions

6

Operational Instructions

11

Storage

15

TABLE OF CONTENTS

Page

Page

WARNING: Before using this equipment you should consult with your personal physician to see if inversion
equipment is appropriate for you. Do not use this equipment without your physician's approval. Do not use
this equipment if you have any of the following conditions or ailments:

To reduce the risk of serious injury, read the following safety instructions before using the
Elite Inversion System.

Extreme obesity
Glaucoma, retinal detachment or conjunctivitis
Pregnancy
Spinal injury, Cerebral Sclerosis, or acutely swollen joints
Middle ear infection
High blood pressure, Hypertension, Recent stroke or Transient ischemic attack
Heart or circulatory disorders for which you are being treated
Hiatus hernia or Ventral hernia
Bone weaknesses including Osteoporosis, Unhealed fractures, Medullary pins, or Surgically
implanted orthopedic supports.
Use of anti-coagulants including Aspirin in high doses.