Wear-Level — F5h
The Wear-Level command is supported as an NOP command for the
purposes of backward compatibility with the ANSI AT attachment standard.
This command sets the Sector Count register to 0x00h.

Table 60: Wear-Level — F5h

Register

D

7

D

6

D

5

D

4

D

3

D

2

D

1

D

0

Feature

X

Sector Count

Completion Status

Sector Number

X

Cylinder Low

X

Cylinder High

X

Drive Head

X

X

X

Drive

Flag

Command

F5h