Shure M367 User Manual

Page 4

Advertising
background image

4

AC OPERATION

Use the supplied power adapter to connect the M367 to a power

outlet.

M367: 100-120 VAC, 50/60 Hz

M367E: 220-240 VAC, 50/60 Hz

The operating voltage can be switched internally (see Internal

Modifiable Functions).

BATTERY OPERATION

Open the battery compartment by grasping the sides of the

compartment, squeezing to release the locks, and pulling the com-

partment outward. Insert two 9-volt batteries.

During battery operation, use the BATT CHECK button. Press

and hold to show battery level on the VU meter. Press once to illu-

minate the VU switch for 10 seconds, or set DIP switch 6 for con-

tinuous illumination (see DIP Switches).

BATTERY LIFE

With two fresh 9-volt alkaline batteries, the M367 operates for

about eight hours. Some mixer features decrease battery life, as il-

lustrated in the following table.

*until Power LED begins to flash, allowing approximately 30 minutes

to replace batteries.

CONNECTING M367 OUTPUTS TO TELEPHONE LINES

Use the XLR outputs at line level to drive dc-biased, "dialed up"

telephone lines. A slight increase in distortion may occur. Use the

M367 limiter with the limiter threshold set to +4 dBm. Modify the

M367 output impedance to 600 Ω for proper fidelity (see Internal

Modifiable Functions). When connecting the M367 to a telephone

line, you must use an FCC-Registered interface adapter between

the mixer and telephone line.

SETTING LEVELS

1. Set the MASTER gain knob to the full off position.
2. Activate the 1 khz tone oscillator by setting the 1 KHZ TONE

switch to ON. Adjust the MASTER gain until the VU meter
needle indicates "0". Adjust the input levels on the equipment
connected to the M367 outputs accordingly. Deactivate the
tone by setting the 1 KHZ TONE switch to OFF.

3. Adjust the Input gain controls based on the incoming signal

levels. The input PEAK LEDs should flicker red only on loud
input peaks.

4. Observe the output on the VU meter and adjust the MASTER

gain to obtain the desired levels. try to keep the average levels
around "0 VU". The PEAK LED adjacent to the VU meter
should illuminate only on loud output peaks.

DIP SWITCHES

Access the DIP switches by removing the battery compartment

and top cover. Use the following table to set the switches
(Bold = factory setting.)

LIMITER THRESHOLD SETTINGS

FIGURE 4

NOTE

Momentary use of headphones or meter illumination will not

appreciably affect battery life.

Mixer Operation

Battery

Current

(mA)

Battery

Life

(hours)*

No Signal

40

9

With +4 dBm continuous output

45

8

With six mics at 12 V phantom power

55

6.5

With six mics at 48 V phantom power

70

5

With output to headphones

50

7

With meter illumination continuously on

75

4.5

NOTE

Appliance inlet is the main disconnect device (to power off the

M367, you must unplug the power supply).

Switch

Function

Up

Down

1

Meter 0 VU

0 VU = +4 dBm

0 VU = +8 dBm

2

Limiter

Threshold

See Figure 4

3

4

Program to

Monitor

Off

On (adds attenu-

ated program signal

in headphones with

Pull/Monitor switch

on)

5

Monitor In

Gain

Normal

High

6

VU Lamp (Batt

Check button)

Timed (Turns off

after 10 seconds)

Toggled (press on,

press off)

7

Phantom

Power

12 Vdc

48 Vdc

1

S701

2 3 4 5 6 7

2

3

Limiter Threshold

= +16 dBm

= +8 dBm

= +4 dBm

= 0 dBm

Advertising