Internal adjustments – Shure M367 User Manual

Page 7

Advertising
background image

7

INTERNAL ADJUSTMENTS

These internal adjustments require only removal of the top

cover:
1. Remove battery compartment.
2. Remove four screws securing two plastic end caps and one

ground-bonding screw on the side opposite the battery com-
part ment.

3. Slowly slide cover up and off chassis.

VCA DISTORTION TRIMPOT (R607)

DO NOT ADJUST! This potentiometer is precisely calibrated on

each mixer for minimum distortion.

VU METER ADJUSTMENT (R684)

This trimpot adjusts the VU meter to indicate 0 VU at a preset

output level. The factory setting is +4 dBm. The user adjustment

range is -10 dBV to +4 dBm (-6 dBV to +8 dBm with DIP switch 1

down).

To set the VU meter to a value other than the factory setting

(0 VU = +4 dBm), proceed as follows:
1. Connect a 600 Ω load to an XLR output set for Line.
2. Connect an ac voltmeter with 1 MΩ or greater input

impedance (Fluke 77 or equivalent) in parallel with the load.

3. Set the 1 kHz tone oscillator switch to the ON position.

4. Adjust the 1 kHz tone oscillator level with the Master gain

con-

trol until the ac voltmeter reading is at the level desired

5. With the M367 top cover removed, adjust the VU Level Cali-

bration trim pot R684 with a screwdriver until the VU Meter
reads 0.

6. For 0 VU settings between +4 and +8 dBm, set internal DIP

switch S701 position 1 "down", and perform steps 1 through 5.

INTERNAL ADJUSTMENTS

FIGURE 5

NOTE

Only qualified service technicians should perform these

modifications.

VU METER

CALIBRATION

TRIMPOT

R684

VCA

DISTORTION

TRIMPOT

R607

DIP SWITCH

S701

(ACCESSED

THROUGH

HOLE IN

UPPER FRONT

PC BOARD)

Advertising