Technical data receiver ek 2013 pll, Technical data – Sennheiser System 2013 PLL User Manual

Page 34

Advertising
background image

2.16

Technical data

Receiver EK 2013 PLL

Frequency range EK 2013-6-D

8 m frequency band

36.64-37.98 MHz

EK 2013-6-1

8 m frequency band

30-36 MHz

EK 2013-6-2

8 m frequency band

35-40 MHz

EK 2013-6-3

8 m frequency band

39-45 MHz

EK 2013-8

4 m frequency band

72.025-75.975 MHz

EK 2013-9

2 m frequency band

173.350-175.02 MHz

Frequency preparation

Phase Lock Loop (PLL) Technique, 16 channels

Modulation type

FM

Rated lift/peak lift

±

8 kHz /

±

12 kHz

Channel grid/switching band width

EK 2013-6-D

40 kHz / 2.34 MHz

EK 2013-6-1

40 kHz / 2 MHz

EK 2013-6-2

40 kHz / 2 MHz

EK 2013-6-3

40 kHz / 2 MHz

EK 2013-8

25 kHz / 4 MHz

EK 2013-9

25 kHz / 2 MHz

Sensitivity
(measured via artificial antenna)

typ. 0.5

µ

V for 26 dB S/N

Neighboring channel selection

typ. 70 dB

LF transmission range

40 - 16,000 Hz

Nonlinear distortion factor
at 1 kHz and rated lift

typ. 1 %

LF output 1:

3.5 mm dia. jack

High:

2 x 0.7 V / 32 U

LF output 2:

2.5 mm dia. jack

Low (hearing aids):

2 x 3 mV / 2 k

Impedance at LF output 2
for connection of hearing aids

in normal operation

3 k

with activated automatic fade-in

80 U to 1 kU adjustable

Operating voltage 2.4 V
Current consumption

approx. 45 mA

Operating time

> 14 hours with RECHARGEABLE battery

pack

BA 2013
> 40 hours with 2 x Alkaline AA cells in B 2013

Battery check

red LED for operating voltage < 2.2 V

Dimensions

18 x 58 x 95 mm

Weight (incl. B 2013)

approx. 130 g

German ZZF Certification No.

A 014 926 B ME (only -6)

Scope of delivery

1 Receiver EK 2013 PLL
1 Battery compartment B 2013

Not responsible for errors. Subject to change without notice.

Advertising