MVS-8000SF

1-8. Checks on Completion of Installation

TP401 (C-7) : CPU half clock signal check
terminal
Use this terminal to check the CPU half clock signal.

TP402 (B-7) : CPU clock signal check terminal
Use this terminal to check the CPU clock signal.

TP900 (M-10), TP1200 (K-10) : ERR check terminal
SDI signal error measuring terminal.

TP201 (L-13) : VD (vertical sync) signal check
terminal
Use this terminal to check the VD signal that is used in this
circuit board.

TP202 (L-12) : CKX (control timing) signal check
terminal
Use this terminal to check the CKX signal that is used in
this circuit board.

TP203 (M-13) : HD (horizontal sync) signal check
terminal
Use this terminal to check the HD signal that is used in this
circuit board.

TP204 (M-12) : FLOE (field odd even) signal check
terminal
Use this terminal to check the FLOE signal that is used in
this circuit board.

TP205 (L-12) : VCLK (clock for video signal)
signal check terminal
Use this terminal to check the clock for video signal.

<LED on the CPU DR module> (C11)
Refer to < LED on the CPU DR module > in “1. CA-44
Board”.

<Switch on the CPU DR module> (C11)
Refer to < Switch on the CPU DR module > in “1. CA-44
Board”.

<Switch>
S2001 (A-5) : JTAG switch
Used only for production in the assembly factory. Set this
switch to ON only when writing program in the JTAG
device with ISP.

S101 (A-8) : CC-CPU reset switch
Pressing this switch initializes the CPU on the CC-90
board.

S400 (A-8) : Monitor reset switch
The reset switch that is used to reset the monitor during
maintenance through the terminal.

<Connector>
CN2001 (A-6) : ISP common connector
Used only for production in the assembly factory. Used for
program writing into the JTAG device with ISP.

CN401 (A-7) : Terminal pin
This pin is connected to the control terminal and used
during maintenance.
Conforms to RS-232C.

<TEST terminal>
E101 (A-5), E103 (D-5), E104 (L-12), E105 (N-8),
E106 (B-8), E107 (B-13), E108 (J-9) : GND terminal
Use this terminal as the earth point for measuring the
respective check terminals.

TP101 (A-3) :

+

+

+

+

+12 V check terminal

+12 V measuring terminal.

TP9501 (A-3) :

+

+

+

+

+3.3 V check terminal

+3.3 V measuring terminal.

TP9001 (A-4) :

+

+

+

+

+1.8 V-1 check terminal

+1.8 V-1 measuring terminal.

TP9301 (A-4) :

+

+

+

+

+1.8 V-2 check terminal

+1.8 V-2 measuring terminal.

TP400 (C-8) : System clock signal check terminal
Use this terminal to check the system clock signal supplied
from CPU module.