Setting the Timed Output:

When a channel is set to Timed Output, triggering the channel will activate the relay for a set
period of time. Factory default is 1 second.
1. The time can be set from 1~60 seconds using the Timer switches on the top of the receiver.
2. Set switches according to the following chart.
NOTE: The time set via the DIP switches applies to all channels programmed for Timed Output.

Sec.

SW1

SW2

SW3

1*

On

Off

Off

2

Off

On

Off

3

Off

Off

On

4

On

Off

On

5

Off

On

On

10

On

On

Off

30

Off

Off

Off

60

On

On

On

*Default setting

Setting the Auxiliary Relay:

Each channel may be individually set to activate a separately timed 12VDC output programmable
from 1 second to 10 minutes. The auxiliary relay provides up to 3A@12VDC*.
1. Connect the auxiliary device to the auxiliary relay. The two auxiliary relay terminals are the

left-most terminals on the terminal block as shown in the diagram below.

2. Select which channels will trigger the auxiliary relay using the Auxiliary Relay DIP switch

(SW8), located on the PCB as shown in the diagram below.

3. If the switch is in the ON position, triggering the

corresponding channel will activate the auxiliary relay.

4. If the switch is in the OFF position, triggering the

corresponding channel will not activate the auxiliary relay.

Setting Auxiliary Relay Timer:
1. Output time can be adjusted from 1 second to 10 minutes

using the auxiliary relay output time potentiometer.

2. Turning the potentiometer clockwise will increase the output time.
3. Turning the potentiometer counterclockwise will decrease the output time.

Use the DIP switch to select the
channel. Default is Channel 1 ON.

PCB

Auxiliary relay time potentiometer

Terminal Block

Auxiliary relay terminals

Top of unit

Timer switches

SW1 SW2 SW3

*Note

Included power supply will not

support loads larger than 500mA.

For larger loads, replace with

appropriate DC power supply.