background image

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

5

Ensure the minimum clearances shown in

Figures 2 and 3 are maintained.

Minimum clearance to combustibles are:

Appliance:

side and back - 0"

floor - 0"

adjacent wall - 6"

ceiling - 37-1/2” (953 mm)

Figure 2

A hearth extension is not required with this

appliance. If a hearth extension is used, do not

block the lower control compartment door. Any

hearth extensions used is for appearance only

and does not have to conform to standard

hearth extension installation requirements.

PREINSTALLATION

Check that all listed parts have been received.

Carefully inspect the heater case and contents

for shipping damage and immediately inform

the dealer from whom you purchased the gas

fireplace if any damage is found.

The appliance is shipped with all gas controls

and components installed and pre-wired. Re-

move the shipping carton. The nailing flanges

are installed at each side of the appliance back-

wards when shipped from the factory to protect

the unit from shipping damage. Remove the

nailing flanges and retain for use when install-

ing the appliance in framing. Remove three

screws and remove the screen panel. Remove

the logs and set aside.

Check Gas Type

This appliance can only be connected to the gas

type specified on the appliance data plate. This

appliance can not be modified in the field for a

different gas type. If the gas type to be used is

not the one specified contact the dealer to

obtain the correct gas appliance.

Note: Illustrations shown in this manual reflect

“typical” installations with nominal dimensions

and are for design and framing reference only.

Actual installations may vary due to individual

design preferences. However, always maintain

minimum clearances to combustible materials

and do not violate any specific installation re-

quirements.

Figure 3

37-1/2" Min.

to Ceiling

(953 mm)

(See Fig. 2)

6" Clearance

to Combustible

Side Wall

Max. Projection (See Fig. 2)

Combustible

Mantel

Combustible

Finished Wall

Materials

Top of Appliance

VF Series

12"

( mm)

2-1/2"

( mm)

8"

( mm)

26"

( mm)

Top of Door Frame

Spacer

6''

8''

10''

22-1/2"

( mm)

18-5/8"

( mm)

14-1/2"

( mm)

Header

1/4" Gap

Required

Note: The following steps represent the normal

sequence of installation. Each installation is

unique, however, and might require a different

sequence.

CAUTION: HEATERS CREATE WARM AIR CUR-

RENTS. THESE CURRENTS MOVE HEAT TO

WALL SURFACES NEXT TO HEATER. INSTALL-

ING HEATER NEXT TO VINYL OR CLOTH WALL

COVERINGS OR OPERATING HEATER WHERE

IMPURITIES IN THE AIR (SUCH AS TOBACCO

SMOKE) EXISTS, MAY DISCOLOR WALLS.

Step 1. Position heater in desired location

(freestanding, onto surround base or into pre-

pared framing) and secure.

Step 2. Plumb gas line. (Gas connections should

only be performed by an experienced, licensed/

certified tradesman.)

Step 3. Assemble logs and test flame appear-

ance.

Step 4. Complete finish wall material, sur-

round and optional hearth extension to your

individual taste.

INSTALLATION STEPS

Built-In Systems

WARNING: DO NOT ALLOW FANS TO

BLOW DIRECTLY INTO THE FIREPLACE.

AVOID ANY DRAFTS THAT ALTER

BURNER FLAME PATTERNS.

WARNING: DO NOT USE A BLOWER IN-

SERT, HEAT EXCHANGER INSERT OR

OTHER ACCESSORY NOT APPROVED

FOR USE WITH THIS HEATER.

Do not burn solid fuels in this listed unvented

gas room heater.

Step 1. Frame VF4000 appliance enclosures

as illustrated in

Figures 4, 5 and 6.

Note: The framed depth (15-1/2" for a flat wall,

29" for a corner VF4000) must always be

measured from a finished surface. If a wall

covering such as drywall is to be attached to

the rear wall, then the dimension must be

measured from the drywall surface.

Note: Framing dimensions in Figures 4 - 6

are calculated for a nailing flange depth of

1/2" (13 mm).

Note: Combustible wall finish materials and/or

surround materials must not be allowed to

encroach the area defined by the appliance

front face (black sheet metal). Never allow

combustible materials to be positioned in front

of or overlapping the appliance front face.

Do not install in the vicinity of gasoline or other

flammable liquids. The heater must be kept

clear and free from these combustible materi-

als and may not be located near where they are

stored.

Clearances

WARNING: DO NOT INSTALL VF SE-

RIES UNVENTED ROOM HEATERS IN

SLEEPING QUARTERS, OR IN RECRE-

ATIONAL VEHICLES.

WARNING: DO NOT INSTALL THE VF

UNVENTED ROOM HEATER:

• WHERE CURTAINS, FURNITURE,

CLOTHING OR OTHER FLAMMABLE

OBJECTS ARE LESS THAN 42" FROM

THE FRONT OF THE UNVENTED ROOM

HEATER.

• IN HIGH TRAFFIC AREAS.

• IN WINDY OR DRAFTY AREAS.