NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

7

Figure 12

White

(Supply)

Black

(Supply)

Bipolar

Terminal

Screw

Blower

(Lower)

Outlet

Black

Wire

Mating

Connectors

Red Wire

120 Vac

60 Hz

Blower Wiring Diagram

}

OFF/ON Blower

Wall Switch

To Fuse or

Circuit Breaker

120V

AC

60Hz

Fireplace

Junction Box

Black

White

Receptacle

Ground Wire

Connection

Note: Supply wires may be alternatively connected to the outlet using the screw terminals,

however the black supply wire must be ganged wired to the same terminal that the pre-wired black

wire is attached to and the white supply wire must be connected to the opposite side of the outlet.

Step 5. Installing the Optional Remote Wall

Switch (VF4000-CMN/P models only) – The

millivolt system comes from the factory wired

as shown in

Figure 10. Select a convenient

location for the remote wall switch and connect

the wiring to the appliance (

Figure 11 ).

CAUTION: DO NOT CONNECT THE OPTIONAL

REMOTE SWITCH TO A 120V POWER SUPPLY.

Note: The optional rocker switch is mounted to

the appliance and wired in the same way as the

remote wall switch.

Figure 11

Step 6. Installing the Optional Forced Air

Blower Kit Wiring – A receptacle plate is

provided for the installation of the FAB-1100

forced air blower kit (optional). Electrical

power must be provided to this plate to oper-

ate the blower.

Route a 3-wire, 120Vac power line with con-

trol switch to the lower left front corner of the

appliance. Supply wires are to be connected to

the outlet as shown in

Figure 12, ensuring that

the polarity (as determined by the colors of the

wires) is exactly as shown. The black and red

wire loop must be left intact, with the mating

connectors connected.

Figure 10

VF4000-CMN/P Series

Wiring Diagram

TPTH

TP

TH

Thermopile

If any of the original wire as supplied must be replaced, it

must be replaced with

Type AWM 105

°

C – 18 GA. wire.

* For Rocker or ON/OFF Wall Switch Attachment Only.

*

*

From Thermocouple

VF4000-CMN/P Series

Optional Wiring Diagram

TPTH

TP

TH

Thermopile

If any of the original wire as supplied must be replaced, it

must be replaced with

Type AWM 105

°

C – 18 GA. wire.

Optional ON/OFF

Wall Switch/Rocker Switch

Factory Wired

Field Wired

*

* For Rocker Switch Attachment Only.

*

From Thermocouple

A. Light the appliance (refer to safety and

lighting instructions on pages 14 and 16).

B. Brush all joints and connections with the

gas leak test solution to check for leaks. If

bubbles are formed, or gas odor is detected,

turn the gas control knob to the “OFF” posi-

tion. Either tighten or refasten the leaking

connection and retest as described above.

C. When the gas lines are tested and leak free,

be sure to rinse off the leak testing solution.

D. When the gas lines are tested and leak free,

observe the individual tongues of flame on the

burner. Make sure all ports are open and

producing flame evenly across the burner. If

any ports are blocked, or partially blocked,

clean out the ports.

An external regulator must be used on all pro-

pane (L.P.G.) heaters, in addition to the regula-

tor fitted to the heater, to reduce the supply tank

pressure to 13" w.c. (maximum).

WARNING: CONNECTING DIRECTLY TO

AN UNREGULATED PROPANE TANK CAN

CAUSE AN EXPLOSION.