To light the burner; rotate the gas valve control

knob counterclockwise to the “ON” position.

Step 14. Installing the Hood Assembly –

Attach the hood assembly over the firebox

opening with three (3) screws.

Step 15. Installing the Screen Assembly –

Position the screen assembly in front of the

firebox opening, with the joint in the gasket

down (

Figure 18 ). Locate the three (3) tabs at

the bottom edge of the frame into the three (3)

brackets at the base of the fireplace front

opening. Lean the frame back towards the

fireplace. Install the three (3) 1/4"-20 x 1"

Phillips pan head screws removed previously

and tighten to secure.

In normal operation, at full rate, after 15 min-

utes the following flame appearance should be

observed:

Rear Burner Flame Characteristics – The rear

flames should be yellow. The flames should

extend about 3 – 4" above the front log for

natural gas and 2 – 3" above for propane

(L.P.G.) gas (

Figure 17 ).

When first lighting the appliance, it will take a

few minutes for the line to purge itself of air.

Once purging is complete, the pilot and burner

will light and operate as indicated in the instruc-

tion manual. Subsequent lightings of the appli-

ance will not require such purging. Inspect the

pilot flame (remove logs, if necessary, handling

carefully).

The pilot flame should be steady, not lifting or

floating. Flame should be blue in color with

traces of orange at the outer edge.

The top 3/8" (10 mm) at the pilot thermocouple

should be engulfed in the pilot flame (NG only).

Replace logs if removed for pilot inspection.

Screws

Step 13. Checking the System – With gas line

installed run initial system checkout before

closing up the front of the unit. Follow the pilot

lighting instructions on pages 14 and 16.

Note: Instructions are also found on the pull

out panel located on the bottom surface of the

appliance.

Figure 16

Figure 18

Standard (Manual)

Version Shown

After setting the logs into position as described

above, ensure they are properly and firmly

situated. The heater will not function as in-

tended if the logs are not correctly positioned.

Periodically check the positioning of the logs.

WARNING: FAILURE TO POSITION THE

PARTS IN ACCORDANCE WITH THESE

DIAGRAMS OR FAILURE TO USE ONLY

PARTS SPECIFICALLY APPROVED WITH

THIS HEATER MAY RESULT IN PROP-

ERTY DAMAGE OR PERSONAL INJURY.

Flame Appearance

REFER TO THE OPERATING INSTRUCTIONS

LOCATED AT THE BACK OF THIS MANUAL

BEFORE LIGHTING THE HEATER TO OBSERVE

THE FLAMES.

Flames from the pilot, front and rear burner

should be visually checked as soon as the

heater is installed. In addition a periodic visual

check of the flames should be made. The pilot

flame should always be present when the heater

is in operation and should just envelope the tip

of the thermocouple (

Figure 15 ).

WARNING: NO ADJUSTMENTS ARE TO

BE MADE TO THE ODS PILOT SYSTEM.

TAMPERING WITH THIS SYSTEM CAN

BE EXTREMELY HAZARDOUS.

Figure 15

An incorrect pilot flame is shown in

Figure 16.

This pilot flame will cause the thermocouple to

cool. When the thermocouple cools, the heater

will shut off. If pilot flame pattern is incorrect,

or if heater shuts off, contact your service

representative.

Figure 17

Main Burner – The flames at the front burner

holes will be blue becoming yellowish as they

hit the bark-like texture of the base and front

face of the front log (

Figure 17 ).

Appliance Operation

WARNING: THE LOWER CONTROL COM-

PARTMENT AREA AND LOWER CONTROL

COMPARTMENT ACCESS DOOR ARE EX-

TREMELY HOT WHEN THE APPLIANCE IS

IN OPERATION. EXERCISE EXTREME CARE

WHEN ACCESSING THIS AREA. TOUCH

ONLY THE FAR ENDS OF THE LOWER

CONTROL COMPARTMENT DOOR WHEN

OPENING WHILE THE APPLIANCE IS HOT.