Troubleshooting – Sony SLV-E180EG User Manual

Page 37

Advertising
background image

36

Additional Information

Symptom

The ON/STANDBY switch
does not function.

The power is turned on but the
VCR does not operate.

The clock has stopped and
“–:– –” lights in the display
window.

The playback picture does not
appear on the TV screen.

The picture is not clear.

The picture rolls vertically
during picture search.

The picture has no sound.

Troubleshooting

If you have any questions or problems not covered below, please consult your
nearest Sony service facility.

Power

Clock

Additional Information

Playback

Symptoms caused by contaminated video heads

• Normal picture

• Rough picture

• Unclear picture

• No picture (or

black & white
screen appears)

Remedy

• Connect the mains lead to mains securely.

• Moisture condensation occurs. Turn the power off,

unplug the mains lead and leave the VCR to dry for
over one hour.

• The clock stops if the VCR is disconnected from the

mains for more than an hour. Reset the clock (and
timer).

• Make sure the TV is set to the video channel. If you are

using a monitor, set it to video input.

• Adjust the tracking with the TRACKING +/– buttons.
• The video heads are dirty (see below). Clean the video

heads using the Sony T-25CLD, E-25CLDR, or T-
25CLW video head cleaning cassette. If these cleaning
cassettes are not available in your area, have the heads
cleaned at your nearest Sony service facility (a
standard service charge will be required). Do not use a
commercially available liquid-type cleaning cassette
other than Sony’s, as it may damage the video heads.

• The video heads may have to be replaced. Consult

your local Sony service facility for more information.

• Adjust the vertical hold control on the TV or monitor.

• The tape is defective. Use a new tape.

terminal

initial contamination

Advertising