Technical specifications – Samsung AM27A1C13 User Manual

Page 22

Advertising
background image

Technical Specifications

MODEL

Standard rating conditions cooling

Performance

Ratings

Type

2 Comp + 2 Room

A/B-unit : 9000

208-230~, 60

20

Cooling capacity

Moisture removal

Indoor Air flow

Sound rating

Btu/h

Pts/h

CFM

dB

V, Hz

A

W

A

in

in

ft

ft

ft

in

lbs

2.46

235

38

1 Unit operation

4.0

860

A-Unit

Flare

1/4''

3/8''

16.4

49' 3''

9' 10''

32 x 11 x 7

21

Electrical

Data

The number of operation

Power source

Ampacity

Watts

Max. TD Fuse/Breaker

Refrigeration

Lines

Indoor unit

Connections

Liquid Line O.D.

Suction Line O.D.

Factory Pre-charge

Max. Line length

Max. Height difference

Dimensions

& Weight

W x H x D

Shipping weight

AM18A1C2

Indoor

AM18A1C09

Outdoor

UM18A1C2

2

1

-

-

55

2 Unit operation

8.0

1720

B-Unit

Flare

1/4''

3/8''

16.4

49' 3''

9' 10''

30 x 24 x 12

110

2 Comp + 2 Room

A/B-unit : 12500

208-230~, 60

20

3.96

290

41

1 Unit operation

5.9

1290

A-Unit

Flare

1/4''

1/2''

16.4

49' 3''

9' 10''

32 x 11 x 7

21

AM26A1C2

Indoor

AM26A1C13

Outdoor

UM26A1C2

-

-

56

2 Unit operation

11.8

2580

B-Unit

Flare

1/4''

1/2''

16.4

49' 3''

9' 10''

39 x 31 x 12

141

8

3

64

7

64

13

Indoor

DB

26.7

80

°C

°F

WB

19.4

67

DB

35.0

95

WB

23.9

75

Outdoor

64

63

32

13

32

19

64

5

64

47

64

11

64

5

64

47

64

11

E-

22

2

1