Deciding on Where to Install the Air Conditioner(cont.)

Piping length and the height.

P

REPARING THE

I

NSTALLATION

A-unit

B-unit

C-unit

Pipe size

Unit

Liquid

1/4

"

1/4

"

1/4

"

GAS

1/2

"

3/8

"

3/8

"

MAX. piping length

A

15 m (49ft 3in)

15 m (49ft 3in)

15 m (49ft 3in)

MAX. height

B

3 m (9ft 10in)

3 m (9ft 10in)

3 m (9ft 10in)

A

B

INDOOR UNIT

OUTDOOR UNIT

Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.

A

B

160 mm
(6 inch)
or more

25 mm (1 inch)

or more

27,000Btu/h

100 mm

(4 inch)

or more

100 mm

(4 inch)

minimum

600 mm

(24 inch)

minimum

600 mm (24 inch)

minimum

100 mm
(4 inch)
minimum

A-unit
13,000 Btu/h

B-unit
7,000 Btu/h

C-unit
7,000 Btu/h

Circuit breaker

(20A)

Main power switch

B
(3 metres/9ft 10in maximum)

A
(15 metres/49ft 3in

maximum)

AM27A1C13

AM27A1C07

UM27A1C3

1,208-230~,60

Indoor unit

Outdoor unit

Power supply

Ø, V, Hz

E-

29

ENGLISH