Roubleshooting – Southbend SIMPLE STEAM COUNTERTOP STEAMERS EZ-5 User Manual

Page 26

Advertising
background image

T

ROUBLESHOOTING

M

ODEL

EZ-3

&

EZ-5

C

OUNTERTOP

S

TEAMERS

P

AGE

26

O

PERATOR

S

M

ANUAL

1178387

REV

7

T

R

O

U

B

L

E

S

H

O

O

T

IN

G

Figure 15

Timer and Buzzer Check

Timer

Buzzer

1. Disconnect power at circuit breaker.

2. Remove control panel.

3. Set timer for one minute and allow to time out. If timer does not run, then replace.

4. Remove buzzer lead wires from timer and terminal block position 6, as shown.

5. Place test leads between positions 1 and 3 on the timer.

6. Check for continuity. If no continuity, replace timer.

7. Place test leads in terminals of buzzer lead wires.

8. Check physical condition of buzzer.

9. Check that resistance is approximately 3.4Kohms. Otherwise, replace buzzer.

Advertising