Figure 16

Door Switch Continuity Check (for units built before January 15, 2001)

Terminal Block

Door Switch

Model EZ-3

Model EZ-5

1. Disconnect power at circuit breaker.

2. Remove control panel.

3. Depress and release door switch actuator rod to make sure door switch is properly actuated.

4. EZ-3: Remove door switch lead wires from terminal block positions 2 and 3, or

EZ-5: Remove door switch lead wires from terminal block position 1 and terminal 2 of the controller.

5. Place test lead as shown inside the terminal connectors of the lead wires.

6. Check for continuity - (there should be NO continuity).

7. Depress door switch actuator rod and check for continuity - (there should be continuity).