Step 3: Electric Connection

A field connection terminal block is located at the rear of the unit, lower left side. A hole is provided for a 3/4"
conduit fitting (solid or flex). The rear cover must be removed to gain access to terminal block (see Figure 2).

Be sure that the input voltage matches the requirement on the serial plate. The unit is factory wired per
customer order.

Field Conversions

You must check if the main power cord to the unit connects to a terminal block, This will reflect that your unit
was built after 02F(June 30, 2002). Rewire heating element connection at the main contactor as per wiring
schematic provided with the unit (inside control panel). If on the back of the unit there are fuses, reflecting
that your unit was built before 02G ( July 1, 2002), use conversion kit .

WARNING

A POSITIVE GROUND CONNECTION IS ESSENTIAL. DO NOT ALLOW ANY TAMPERING OR
ADJUSTMENT OF ANY CONTROL OR WIRING. THE UNIT IS FACTORY SET. ADJUSTING ANY
INTERNAL COMPONENT CAN VOID THE WARRANTY.

All 208-220-240 and 480 volt units will have three terminal block sections, “L1-L2-L3”, for use with either 3-
wire 3-phase or 2-wire, single-phase, 50 or 60 Hz. All 380V and 415V units will have four terminal block
sections, “L1-L2-L3-N,” for use with European style 4-wire 3-phase with neutral.

Figure 2

Rear Cover

Terminal

Block

3/4" Conduit

Fitting Hole

Serial

Plate