Console Display

If Console only has partial display and all connections

are fine, replace the Console.

If the above steps do not resolve the problem, contact

Customer Care for further assistance.

HR cable connection at Console

Make sure cable is connected securely to Console.

HR cable box connection (recumbent only)

Make sure cables from handlebars and cable to

Console are secure and undamaged. Some models may

require the seat back be raised to access cable box.

Sensor grip

Make sure hands are centered on HR sensors. Hands

must be kept still with relatively equal pressure

applied to each side.

Dry or calloused hands

Sensors may have difficulty with dried out or calloused

hands. A conductive electrode cream such as

SIGNACREME® or Buh-Bump™ can help make better

conduct. These are available on the web or at medical

or some larger fitness stores.

Handlebars (recumbent only)

If tests reveal no other issues, Handlebars should be

replaced.

Unit operates but Contact HR not displayed

Console (upright only)

If tests reveal no other issues, Console should be

replaced.

Check data cable integrity

All wires in cable should be intact. If any are cut or

crimped, replace cable.

Check data cable connections/orientation

Insure cable is connected securely and oriented

properly. Small latch on connector should line up and

snap into place.

Console displays "E2" error code

Console Electronics

If tests reveal no other issues, Console should be

replaced.

Check data cable integrity

All wires in cable should be intact. If any are cut or

crimped, replace cable.

Check data cable connections/orientation

Insure cable is connected securely and oriented

properly. Small latch on connector should line up and

snap into place.

Check magnet position (requires shroud removal)

Magnet should be in place on flywheel. If no magnet

is present, replace the flywheel or the entire base unit

(if unable to replace flywheel).

No speed/RPM reading, Console displays "Pedal" error

code

Check RPM Sensor (requires shroud removal)

RPM sensor should be aligned with magnet and

connected to data cable. Realign sensor if necessary.

Replace if there is any damage to the sensor or the

connecting wire.

Check data cable integrity

All wires in the cable should be intact. If any are cut

or crimped, replace cable.

Check data cable connections/orientation

Insure cable is connected securely and oriented

properly. Small latch on connector should line up and

snap into place.

Reset Machine (if equipped with reset button)

Unplug unit from electrical outlet for 3 minutes.

Reconnect to outlet. After the Console powers up,

press "reset".

If bike has batteries, check Battery Level icon on

console or check batteries.

If the battery level shows low or no power, replace

the batteries.

Check magnet position (requires shroud removal)

Magnet should be in place on flywheel. If no magnet

is present, replace flywheel or entire base unit.

Console shuts off (enters sleep mode) while in use

Check RPM Sensor

Contact Customer Care for further assistance.