Sony MZ-R35 User Manual

Page 33

Advertising
background image

33

-EN

Error message

NO SIGNAL

P/B ONLY

PROTECTED

SORRY

TEMP OVER

TR FULL

TrPROTECT

Meaning/Remedy

•The recorder could not detect digital input signals.

b Make sure that the source is connected firmly (page 11).

•You tried to record or edit on a premastered MD (P/B means

playback.)

b Insert a recordable MD.

•You tried to record or edit on a MD with the tab in the record-

protect position.
b Slide the tab back (page 28).

•You tried to erase a track mark while playing the MD or at the

beginning of the first track.

•You tried to erase a track mark to combine tracks the recorder

cannot combine (caused by system limitation).

•Heat has built up in the recorder.

b Let the recorder cool down.

•There is no more space for new data when you are editing the

MD.
b Erase unnecessary tracks (page 21).

•You tried to record or edit on a track that is protected from

erasing.
b Record or edit on other tracks.