Installation procedures – Sony 560TVL User Manual

Page 9

Advertising
background image

• Use the lens connector shown in the following figure. If the dimensions of the

connector are not correct, it may damage the camera, or the lens may not be
installed firmly.

• If the lens is too heavy, the camera becomes unbalanced and there may be

problems. Use a lens that weighs less than 450g.

• When adjusting the Automatic Level Control (ALC) of an auto iris lens, use Av

mode if available. If you use the Pk mode, the picture brightness may change
continuously.

Notes

COLOR CCD CAMERA

COLOR CCD CAMERA

User’s Manual

User’s Manual

17

16

Installation Procedures

Before installing a lens, identify whether the lens to be installed is a C-Mount or CS-Mount.
This camera is set for a CS-Mount Lens by default. To install a C-Mount Lens, a
simple modification is required.

• When Using a CS Mount Lens

Remove the protective glass cover at the front of this product and turn the CS-
Mount Lens clockwise to install it. And set focus of camera using Back Focus
Control Lever of camera side after combining CS-Mount lens.

When Using C/CS Mount Lens

C-Mount Lens: 10mm or less
CS-Mount Lens: 5mm or less

3. Remove the cover of the auto iris lens connector plug and solder the lens cable to

the connector pin of the plug.

4. Fit the cover of the auto iris lens connector

plug, remove the protective glass cover
from the front of the camera, and fasten
the auto iris lens by turning it clockwise.

• For a Video Drive Lens

Pin 1: Red (Power)
Pin 2: NC
Pin 3: White (Video Signal)
Pin 4: Black (Ground)

• For a DC Drive Lens

Pin 1: Damping -
Pin 2: Damping +
Pin 3: Drive +
Pin 4: Drive -

5. Set focus of camera using Back Focus Control

Lever of camera side after combining Auto
Iris lens.

Back Focus Control Lever

No. 3 Pin

No. 1 Pin

connector

Lens cable

No. 4 Pin

No. 2 Pin