Superior SSDVT-3328CNM User Manual

Page 10

Advertising
background image

0

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Burner air shutter adjustment

adjustment rod up

(Fully open position)

air shutter

adjustment rod down

(minimum air opening

position)

Burner tube

adjustment setscrew

electronic appliance checkout

To light the burner, refer to the lighting instruc-

tions on Pages 18 & 19. Ensure the igniter

lights the pilot. The pilot flame should engulf

the flame sensor as shown in Figure 13.

With proper care and maintenance, your appli-

ance will provide many years of enjoyment. If

you should experience any problem, first refer

to the troubleshooting guide in this manual.

If problem persists, contact your Lennox

distributor.

WirinG diaGraM

The wiring diagrams are provided here for

reference purposes only (Figures 14 & 15 ).

This information is also provided on schemat-

ics found on pullout lighting instruction labels

located within the control compartment attached

to the gas control valve.

caution: LaBeL aLL Wires prior to dis-

connection WHen serVicinG controLs.

WirinG errors can cause iMproper and

danGerous appLiance operation.

Figure 13

3/8" to /2"

(9 -3 mm)

Ground

electrode

Flame rod

Hot surface

igniter

proper Flame

adjustment

pilot

nozzels

eLectronic piLot asseMBLY

proper pilot Flame appearance

thermocouple

thermopile

pilot

nozzels

sit MiLLiVoLt piLot asseMBLY

3/8" Min.

(9 mm)

igniter rod

Hood

proper pilot Flame appearance

proper pilot Flame appearance

thermocouple

thermopile

pilot

nozzels

3/8" Min.

(9 mm)

/8" Min.

(3 mm)

igniter rod

Hood

HoneYWeLL MiLLiVoLt piLot asseMBLY

Millivolt appliance checkout
The pilot flame should be steady, not lifting

or floating. Flame should be blue in color with

traces of orange at the outer edge.
The top 3/8" (10 mm) at the pilot generator

(thermopile) and the top 1/8" minimum (tip)

of the quick drop out thermocouple should be

engulfed in the pilot flame. The flame should

project 1" (25 mm) beyond the hood at all three

ports. See Figure

11 or 12.

To light the burner, refer to the lighting instruc-

tions on Pages 16 & 17.

ref. air shutter patent:

u.s. pat. 5,553,603

Figure 10

Figure 12

Figure 11

Main Burner Factory air shutter

opening setting - inches (millimeter)

Model

natural

Gas

propane

Gas

ssdVt-3328

ssdVr-3328

/32

(0.826 mm)

5/6

(7.94 mm)

Advertising