NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

conGratuLations!

In selecting this SUPERIOR Direct-Vent Gas Appliance you have chosen the finest and

most dependable fireplace to be found anywhere. A beautiful, prestigious, alternative

to a wood burning fireplace. Welcome to a Family of tens of thousands of satisfied

SUPERIOR Fireplace Owners.

Please read and carefully follow all of the instructions found in this manual. Please

pay special attention to the safety instructions provided in this manual. The Care and

Operation Instructions included here will assure that you have many years of depend-

able and enjoyable service from your SUPERIOR product.

taBLe oF contents

Introduction ......................................Page 2
General Information ..........................Page 2
Gas Controls Access .........................Page 3
Operation / Care of Your Appliance ...Page 4
Variable Flame Adjustment ................Page 4
Maintenance ......................................Page 5
Front Glass Enclosure Panel,
Removal and Installation .................Page 6
Install Volcanic Stone,
Embers & Logs .................................Page 7
Burner Flame Appearance & Sooting Page 9
Burner Flame Adjustments ................Page 9
Millivolt Appliance Checkout .............Page 10
Electronic Appliance Checkout ..........Page 10
Wiring Diagrams ...............................Page 11
Warranty ...........................................Page 11
Product Reference Information .........Page 11
Accessory Components ....................Page 13
Lighting Instructions – Millivolt ........Page 16
Lighting Instructions – Electronic .....Page 18
Maintenance Schedule ......................Page 20
Troubleshooting Guide – Millivolt......Page 21
Troubleshooting Guide – Electronic ..Page 22
Replacement Parts List .....................Page 23

introduction

The Fireplace models covered in this manual

are Direct-Vent sealed combustion gas fireplace

heaters designed for residential application.

Direct-Vent appliances operate with the com-

bustion chamber completely isolated from the

indoor environment. All air for combustion is

brought in from the outside and exhaust gases

are vented through the same direct vent, co-axial

(intake/exhaust) vent system.

electronic Models -
Electronic models have a fixed rate gas valve.

The BTU Input for electronic models is shown

in Table 2:

Gas pressure - all Models

Tables 3, 4 and 5 show the appliances' inlet

gas pressure requirements:

electronic Models with Fixed rate Gas Valve

natural and propane Gas

Model series

input rate (Btu / Hr)

ssdVt/r-3328

7,500

Table 2

inlet Gas supply pressure

(all models)

Fuel #

Minimum

Maximum

natural Gas

5.0" Wc

(.24 kpa)

0.5" Wc

(2.6 kpa)

propane

.0" Wc

(2.74 kpa)

3.0" Wc

(3.23 kpa)

Table 3

input (Btu) Manually-Modulated Gas

Valves (millivolt models)

naturaL & propane Gas

Models

input rate (Btu / Hr)

ssdVt/r-3328

7,500 high

3,500 low

Table 1

Provide adequate clearances around air open-

ings and adequate accessibility clearance for

service and proper operation. Never obstruct

the front openings of the appliance.

these appliances are designed to operate on

natural or propane gas only. do not use any

other fuels. the use of other fuels, or combi-

nation of fuels, will degrade the performance

of this system and may be dangerous.

These fireplaces are designed as supplemen-

tal heaters. Therefore, it is advisable to have

an alternate heat source when installed in a

dwelling.

Millivolt Models - Btu input

Millivolt models come standard with the manu-

ally-modulated gas valve; flame appearance and

heat output can be controlled at the gas valve.

The BTU Input for millivolt models is shown

in Table 1:

The Millivolt appliances have a millivolt gas

control valve with piezo ignition system provides

safe, efficient operation. If any optional acces-

sories which require electrical power are being

installed, the electrical power must be provided

at the time of appliance installation.

The Electronic appliances have an electronic

intermittent pilot system provides safe, efficient

operation. External electrical power is required

to operate these appliances.

These appliances comply with National Safety

Standards and are tested and listed by Omni-Test

Laboratories (Report No. 116-F-29-5) to ANSI

Z21.88 (in Canada, CSA-2.33), and CAN/CGA-

2.17-M91 in both USA and Canada, as vented

gas fireplace heaters.

The Installation must conform to local codes

or, in the absence of local codes, with the

National Fuel Gas Code, ANSI Z223.1/NFPA

54-latest edition, or the Natural Gas and

Propane Installation Code, CSA B149.1-latest

edition. The appliance, when installed, must

be electrically grounded in accordance with

local codes or, in the absence of local codes,

the latest edition of the National Electrical Code,

ANSI/NFPA 70, or the Canadian Electrical Code,

CSA C22.1 - latest editions.

GeneraL inForMation

Note: Installation and repair should be per-

formed by a qualified service person. The

appliance should be inspected annually by a

qualified professional service technician. More

frequent inspections and cleanings may be

required due to excessive lint from carpeting,

bedding material, etc.

It is imperative that the control compartment,

burners and circulating air passage ways of

appliance be kept clean.

S'assurer que le brùleur et le compartiment des

commandes sont propres. Voir les instructions

d'installation et d'utilisation qui accompagnent

l'appareil.