9-3

(3) Send out one block data (Transmit – the data more than two characters)

Step 1:

Enable TXC signal, and the bit 0 of the address of offset+4 just sets “1”.

Step 2:

Send out the data. (Write all data to the offset+0 of the current COM port address)

Step 3:

Wait for the buffer’ s data empty. Check transmitter holding register (THRE, bit 5 of the address of
offset+5), and transmitter shift register (TSRE, bit 6 of the address of offset+5) are all sets must be
“0”.

Step 4:

Disabled TXC signal, and the bit 0 of the address of offset+4 sets “0”

(4) Receive data

The RS-485’ s operation of receiving data is in the same of the RS-232’ s.

(5) Basic Language Example

a.) Initial 86C450 UART

10

OPEN “COM1:9600,m,8,1”AS #1 LEN=1

20

REM Reset DTR

30

OUT &H3FC, (INP(%H3FC) AND &HFA)

40

RETURN

b.) Send out one character to COM1

10

REM Enable transmitter by setting DTR ON

20

OUT &H3FC, (INP(&H3FC) OR &H01)

30

REM Send out one character

40

PRINT #1, OUTCHR$

50

REM Check transmitter holding register and shift register

60

IF ((INP(&H3FD) AND &H60) >0) THEN 60

70

REM Disable transmitter by resetting DTR

80

OUT &H3FC, (INP(&H3FC) AND &HEF)

90

RETURN

c.) Receive one character from COM1

10

REM Check COM1: receiver buffer

20

IF LOF(1)<256 THEN 70

30

REM Receiver buffer is empty

40

INPSTR$”

50

RETURN

60

REM Read one character from COM1: buffer

70

INPSTR$=INPUT$(1,#1)

80

RETURN