Superior NMC004-TD User Manual

Page 2

Advertising
background image

2

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

These appliances are designed to operate
on natural or propane gas only.

On Millivolt models the Input of the appliance
can be varied from 13,500 to 17,500 BTU/HR.
On Electronic models the input is fixed at
17,500 BTU/HR.

CONGRATULATIONS!

In selecting this SUPERIOR Direct-Vent Gas Appliance you have chosen the finest and
most dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to
a wood burning fireplace. Welcome to a Family of tens of thousands of satisfied
SUPERIOR Fireplace Owners.

Please read and carefully follow all of the instructions found in this manual. Please pay
special attention to the safety instructions provided in this manual. The Homeowner's
Care and Operation Instructions included here will assure that you have many years of
dependable and enjoyable service from your SUPERIOR product.

INTRODUCTION

The Fireplace models covered in this manual
are Direct-Vent sealed combustion gas fire-
place heaters designed for residential applica-
tion. Direct-Vent appliances operate with the
combustion chamber completely isolated from
the inside atmosphere. All air for combustion
is brought in from the outside and exhaust
gases are vented through the same Direct
Vent, vent system.

TABLE OF CONTENTS

General Information ......................... page

2

Operation/Care of Your Appliance .... page

3

Gas Control/Compartment Access ... page

3

Variable Flame Adjustment

(Millivolt) ....................................... page

4

Glass Cleaning ................................. page

4

Maintenance .................................... page

4

Maintenance Schedule ..................... page

5

Front Glass Enclosure Panel,

Removal and Installation ............... page

6

Burner Adjustments ......................... page

6

Flame Appearance and Sooting ....... page

6

Adjustment ...................................... page

6

Log Placement ................................. page

7

Glowing Embers Placement ............. page

7

Millivolt Appliance Checkout ........... page

8

Electronic Appliance Checkout ......... page

8

Wiring Diagrams .............................. page

8

Warranty .......................................... page

9

Replacement Parts .......................... page

9

Product Reference Information ....... page

9

Accessory Components ................... page

9

Millivolt Lighting Instructions .......... page 12

Electronic Lighting Instructions ....... page 14

Millivolt Troubleshooting Guide ........ page 16

Electronic Troubleshooting Guide ..... page 17

Replacement Parts List ..................... page 18

Maximum manifold pressure is 3.5 in. w.c.
(0.87 kPa) for natural gas and 10 in. w.c.
(2.49 kPa) for LP/Propane gas.

Do not use these appliances if any part has
been under water. Immediately call a qualified,
professional service technician to inspect the
appliance and to replace any parts of the
control system and any gas control which
have been under water.

WARNING: IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE. REFER TO THIS
MANUAL. FOR ASSISTANCE OR ADDI-
TIONAL INFORMATION CONSULT A
QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.

GENERAL INFORMATION

Note: Installation and repair should be per-
formed by a qualified service person. The
appliance should be inspected annually by a
qualified professional service technician. More
frequent inspections and cleanings may be
required due to excessive lint from carpeting,
bedding material, etc.

It is imperative that the control compartment,
burners and circulating air passage ways of
the appliance be kept clean.

S'assurer que le brùleur et le compartiment
des commandes sont propres. Voir les in-
structions d'installation et d'utilisation qui
accompagnent l'appareil.

Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.

Due to high temperatures the appliance should
be located out of traffic and away from furni-
ture and draperies. Locate furniture and win-
dow coverings accordingly.

WARNING: THESE FIREPLACES ARE
VENTED HEATERS. DO NOT BURN
WOOD OR OTHER MATERIAL IN THESE
APPLIANCES.

The millivolt appliances are designed to oper-
ate on either natural or propane gas. A millivolt
gas control valve with piezo ignition system
provides safe, efficient operation.

External electrical power is required to operate
the optional electrically powered components
if installed. Electrical power must be wired
during appliance installation.

The electronic appliances are designed to op-
erate on either natural or propane gas. An
electronic intermittent pilot system provides
safe, efficient operation. External electrical
power is required to operate these units.

These appliances comply with National Safety
Standards and are tested and listed by Omni
Test Laboratories (Report No. 116-F-17-4) to
ANSI Z21.88-2002 (in Canada, CSA-2.33-
2002), and CAN/CGA-2.17-M91 in both USA
and Canada, as vented gas fireplace heaters.

Installation must conform to local codes. In
the absence of local codes, installation must
comply with the current National Fuel Gas
Code, ANSI Z223.1 (NFPA 54). (In Canada, the
current CAN/CGA B149 installation code.) Elec-
trical wiring must comply with local codes. In
the absence of local codes, installation must
be in accordance with the National Electrical
Code, NFPA 70 - (latest edition). (In Canada,
the current CSA C22.1 Canadian Electric Code.)

DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.

.

o

N

l

e

d

o

M

e

z

i

s

e

c

i

f

i

r

O

l

a

r

u

t

a

N

e

n

a

p

o

r

P

0

0

4

-

T

D

5

4

#

8

4

0

.

0

h

c

n

i

0

0

4

-

R

D

Advertising
This manual is related to the following products: