Superior NMC004-TD User Manual

Page 5

Advertising
background image

5

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Periodically (After the Burning Season)

Maintenance Task

Accomplishing Person

Procedure

Cleaning Firebox Interior

Check Flame Patterns and Flame Height

Checking Vent System

Cleaning Front Glass Enclosure Panel

Homeowner

Homeowner

Homeowner

Homeowner

Carefully remove logs, Rockwool and volcanic
stone if used. Vacuum out interior of the
firebox. Clean firebox walls and log grate.
Replace logs, Rockwool and volcanic stone as
detailed in this manual.

Refer to

Figure 7 on page 7 and verify the

flame pattern and height displayed by the
appliance conforms to the picture. Flames
must not impinge on the logs.

Inspect the vent system at the top and at the
base (within the firebox) for signs of blockage
or obstruction. Look for any signs of disloca-
tion of the vent components.

Clean as necessary following the directions
provided in this manual. DO NOT TOUCH OR
ATTEMPT TO CLEAN GLASS WHILE HOT
.

Maintenance Schedule

Annually (Before the onset of the Burning Season)

Maintenance Task

Accomplishing Person

Procedure

Inspecting/Cleaning Burner, Logs
and Controls

Check Flame Patterns and Flame Height

Inspecting/Cleaning Pilot and Burner

Checking Vent System

Appliance Checkout

Replacing Rockwool Ember Materials

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Homeowner/Qualified Services Technician

Inspect valve and ensure it is properly operat-
ing. Check piping for leaks. Vacuum the
control compartment, fireplace logs and burner
area.

Refer to

Figure 7 on page 7 and verify the

flame pattern and height displayed by the
appliance conforms to the picture. Flames
must not impinge on the logs.

Refer to

Figure 8 on page 7 (Millivolt) or

Figure 9 on page 7 (Electronic). Remove any
surface build-up on pilot and burner assem-
bly. Wipe the pilot nozzles, ignitor/flame rod
and hood. Ensure the pilot flame engulfs the
flame sensor as shown.

Inspect the vent system at the top and at the
base (within the firebox) for signs of blockage
or obstruction. Look for any signs of disloca-
tion of the vent components.

Perform the appropriate appliance checkout
procedure detailed in this manual.

Remove old ember materials and vacuum the
screened rockwool placement area. Place new
rockwool as described in this document.

Advertising
This manual is related to the following products: