NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Electronic Appliance Checkout

To light the burner, turn ‘ON’ the optional
remote wall switch and turn the gas control
switch to the “ON” position. Ensure the ignitor
lights the pilot. The pilot flame should engulf
the flame rod as shown in

Figure 11.

Figure 11

With proper care and maintenance, your ap-
pliance will provide many years of enjoy-
ment. If you should experience any problem,
first refer to the trouble shooting guide in this
manual. If problem persists, contact your
Lennox distributor.

With proper care and maintenance, your ap-
pliance will provide many years of enjoy-
ment. If you should experience any problem,
first refer to the trouble shooting guide in this
manual. If problem persists, contact your
Lennox distributor.

WIRING DIAGRAM

The wiring diagrams are provided here for
reference purposes only

(Figures 12, 13 and

14 on page 9). This information is also pro-
vided on schematics found on pullout lighting
instruction labels located within the control
compartment attached to the gas control valve.

CAUTION: LABEL ALL WIRES PRIOR TO
DISCONNECTION WHEN SERVICING CON-
TROLS. WIRING ERRORS CAN CAUSE IM-
PROPER AND DANGEROUS APPLIANCE OP-
ERATION.

SIT and Honeywell Millivolt Appliance Checkout

The pilot flame should be steady, not lifting or
floating. Flame should be blue in color with
traces of orange at the outer edge.

The top

³⁄₈" (10 mm) at the pilot generator

(thermopile) and the top

¹⁄₈" min (tip) of the quick

drop out thermocouple should be engulfed in the
pilot flame. The flame should project 1" (25 mm)
beyond the hood at all three ports (

Figure 9 - SIT,

Figure 10 - Honeywell ).

To light the burner, refer to the lighting in-
structions on

pages 12 and 13 for Honeywell

and SIT millivolt gas valves).

Figure 10

Figure 9

¹⁄₈" Min

(3 mm)

Thermocouple

Ignitor Rod

Hood

³⁄₈" Min

(9 mm)

Thermopile

MILLIVOLT HONEYWELL

Pilot

Nozzels

SIT MILLIVOLT

Thermocouple

Hood

Ignitor Rod

³⁄₈" Min

(9 mm)

Thermopile

Pilot
Nozzels

ELECTRONIC

Proper Flame

Adjustment

Pilot
Nozzle

3/8 To 1/2 Inch

(9 mm to 13 mm)

Ground
Electrode

Flame Rod

Hot Surface

Igniter

Advertising
This manual is related to the following products: