If a problem occurs, Error checklist – Sennheiser W300 IEM User Manual

Page 36

Advertising
background image

34

If a problem occurs ...

Error checklist

If a problem occurs that is not listed in the above table or if the problem cannot be solved with the proposed
solutions, please contact your local Sennheiser agent for assistance.

Problem

Possible cause

Possible solution

No operation indication

Batteries are flat or
accupack is flat (receiver only)

Replace the batteries or
recharge the accupack

No mains connection (transmitter
only)

Check the connections of the mains
unit

No RF signal

Transmitter and receiver are not on
the same channel

Set transmitter and receiver to the
same channel

Transmission range is exceeded

Check the squelch threshold setting
(see “Adjusting the squelch
threshold (receiver only)” on
page 29
)

or reduce the distance between
transmitting antenna and receiver

RF signal available,
no audio signal,
“MUTE” display appears on
the display panel

Transmitter is set to mono operation
and the pilot tone evaluation of the
receiver is activated

Deactivate the pilot tone evaluation
on the receiver

Receiver’s squelch threshold is
adjusted too high

See “Adjusting the squelch threshold
(receiver only)” on page 29)

Audio signal has a high level
of background noise

Transmitter sensitivity is adjusted
too low

See “Adjusting the sensitivity
(transmitter only)” on page 30

Audio signal is distorted

Transmitter sensitivity is adjusted
too high

See “Adjusting the sensitivity
(transmitter only)” on page 30

No access to a certain channel

During scanning, an RF signal has
been detected on this channel and
the channel has been locked

See “Scanning the channel banks for
free channels (receiver only)” on
page 28

ew300_350_IEM_INT.book Seite 34 Freitag, 7. März 2008 8:55 08