5

The channel bank system

The ew 300 IEM G2 systems are available in six UHF frequency ranges with 1440 transmission/receiving frequencies
per frequency range. Please note: Frequency usage is different for each country. Your Sennheiser agent will have all
the necessary details on the available legal frequencies for your area:

The transmitters and the receiver of the ew 300 IEM G2 systems have nine channel banks with up to 12 switchable
channels each.

The channel banks “1” to “8” have up to 12 switchable channels that are factory-preset to a transmission/receiving
frequency (see enclosed frequency table). These transmission/receiving frequencies cannot be changed but have
been preset so that e.g. country-specific regulations on frequency usage are taken into account (see “Type
approvals” on page 39)
. For detailed information, please refer to the enclosed frequency data sheets and to the
country-specific frequency and transmission power overviews.

An advantage of the factory-preset frequencies is that
y the system is ready for immediate use after switch-on,
y several transmission systems can be operated simultaneously on the preset channels without causing

intermodulation interference.

Delivery includes

Depending on the purchased system, delivery includes:

Range A:

518 to 554 MHz

Range B:

626 to 662 MHz

Range C:

740 to 776 MHz

Range D:

786 to 822 MHz

Range E:

830 to 866 MHz

Range G:

572 to 608 MHz

ew 300 IEM G2 system

SR 350 IEM G2

y 1 EK 300 IEM G2 stereo receiver
y 1 SR 300 IEM G2 stereo transmitter
y 2 batteries
y 1 telescopic antenna for SR 300 IEM G2
y 1 NT 2-1 mains unit
y 1 pair of IE 4 earphones
y Instructions for use
y 1 frequency data sheet
y Frequency and transmission power overviews

y 1 SR 350 IEM G2 stereo twin transmitter
y 2 telescopic antennas for SR 350 IEM G2
y 1 mains cable
y Instructions for use
y 1 frequency data sheet
y Frequency and transmission power overviews

1...8

U

Bank

Bank

Channel 1

Channel 2

Channel 12

Channel 1

Channel 2

Channel 12

Factory-preset frequency

Factory-preset frequency

Factory-preset frequency

frequency

selectable frequency

selectable frequency

selectable

ew300_350_IEM_INT.book Seite 5 Freitag, 7. März 2008 8:55 08