Disconnecting all connec- tions, Entering advanced setup menu, Setting auto logout time – Sharp XG-P610X User Manual

Page 38: Data port setting, Controlling the projector using rs-232c or telnet, D]disconnect all), A]advanced setup), Advanced[1]auto logout time), Advanced[2]data port)

Advertising
background image

-38

Controlling the Projector Using RS-232C or Telnet

Disconnecting All Connec-
tions

([D]Disconnect All)

It is possible to disconnect all the TCP/IP connec-
tions currently recognized by the projector. Even if
the COM Redirect port is fixed in the Busy status
due to a problem, it is possible to force the Ready
status back by carrying out this disconnection.

1

1

1

1

1 Enter “d” and press the “Enter” key.
2

2

2

2

2 Enter “y” and press the “Enter” key.

Note

• If Disconnect All is performed, the connection to

the projector via network will be forcibly discon-
nected.

Entering ADVANCED
SETUP MENU

([A]Advanced Setup)

Enters ADVANCED SETUP MENU.

1

1

1

1

1 Enter “a” and press the “Enter” key.

Setting Auto Logout Time

(ADVANCED[1]Auto Logout Time)

If there is no input after a fixed time, the projector
automatically disconnects network connection using
the Auto Logout function. It is possible to set the time
until the projector is automatically disconnected in
units of a minute (from 1 to 65535 minutes).

1

1

1

1

1 Enter “1” and press the “Enter” key.
2

2

2

2

2 Enter numerical value and press the “Enter” key.

Display set numerical value (*).

Note

• If the set value is made 0, the Auto Logout func-

tion is disabled.

• If an invalid number is entered, an error message

(“Parameter Error!”) will be displayed and the
screen returns to the ADVANCED SETUP MENU.

Data Port Setting

(ADVANCED[2]Data Port)

Setting of TCP port number. It is possible to set in
the range of 1025 to 65535.

1

1

1

1

1 Enter “2” and press the “Enter” key.
2

2

2

2

2 Enter numerical value and press the “Enter” key.

Display set numerical value (*).

Note

• Set according to need. Normally, use with the

factory default setting.

setup>d
Disconnect All Connections(y/n)?y
Now Disconnecting...

1
2

setup>a
******************** ADVANCED SETUP MENU ***********************
[1]Auto Logout Time

[2]Data Port

[5]Network Ping Test
[6]Accept IP Addr(1)

[7]Accept IP Addr(2)

[8]Accept IP Addr(3)

[9]Accept All IP Addr

[0]Search Port

[!]Restore Default Setting
[Q]Return to Main Menu

advanced>

1

advanced>1
Valid range

: 0 to 65535 (minute)

note: if you enter “0”, auto logout function will be disable.
Auto Logout Time : 5
Please Enter

:15

(change) —> 15

1

2

*

advanced>2
Valid range

:1025 to 65535

Data Port

:10002

Please Enter

:10005

(change) —> 10005

1

2

*

Advertising