Menu Configuration

RS-485 communication control

Connection

Using a RS-485 communication, it will be able to control the OSD menu at the
SAMSUNG TECHWIN System Controller or DVR.
(1) The case which it controls from the PC

Using a RS-485 converter, It connects to RS-485 control cable outside camera
and serial cable

EX) SERIAL PORT OF THE PC(COM1)

SERIAL CABLE

RS-485 CONVERTER

RS-485

CONTROL CABLE

(2)The case which it controls from the DVR or System Controller

It connects the RS-485 control cable in the connection terminal of 485 control
boards which are connected with the DVR or System Controller.

Connecting to RS-485 Control Cable

• When you construct external control systems for a camera control, please use to

the SAMSUNG TECHWIN PROTOCOL or PELCO-D PROTOCOL.

• When you connecting to RS-485 control cable, please peel off the outer skin

inside the RS-485 control cable.

Notes

CONTROL CABLE

SPEC

RED (TRX+)

RS-485+

WHITE(TRX-)

RS-485-

Setup Menu

LENS

• DC

EXPOSURE

• SHUTTER

• AGC

• SENS-UP

• RETURN

WHITE BALANCE

• ATW

• MANUAL

• AWC

SET

• OUTDOOR • INDOOR

BACKLIGHT

• OFF

• WDR

• BLC

SSNR

• ON

• OFF

DAY/NIGHT

• COLOR

• B/W

• AUTO

IMAGE ADJUSTMENT

• FREEZ

• V-REV

• H-REV

(IMAGE ADJ.)

• D-ZOOM

• SHARPNESS

• RETURN

SPECIAL

• CAMTITLE • MOTION DET • PRIVACY

• DIS

• COMM ADJ

• LANGUAGE

• RESET

• RETURN

EXIT

* RS-485 Communication establishment initial value

485 Control Board Connection Port

RS-485 Control Port

(+) CONNECTION TERMINAL

RED (TRX+)

(

-

) CONNECTION TERMINAL

WHITE (TRX-)

Item

Initial value

Camera ID

BAUD RATE

UART MODE

PET PKT

1

9600

8-NONE-1