Warning, Avertissement – Superior SDV35 User Manual

Page 9

Advertising
background image

9

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

DETAILED INSTALLATION STEPS

The appliance is shipped with all gas controls

and components installed and pre-wired.

1. Remove the shipping carton. Remove the

shipping pad, exposing the front glass

door.

2. Remove the bottom louvered control panel

per instructions on Page 26 (see Control

Compartment Access / Louver Panel Instruc-

tions).

3. Open the two latches (located under the fire-

box floor) securing the glass door. Remove

the door by tilting it outward at the bottom

and lifting it up. Set the door aside protecting

it from inadvertent damage. See Figure 55

on Page 30.

4. Remove the top louvered panel and locate

the pressure relief plates.

5. Lift the pressure relief plates and remove

the cardboard from beneath each plate (be

careful not to damage the white gasket).

See Figure 10.

Figure 10

REMOVE

CARDBOARD

BEFORE USING

REMOVE

CARDBOARD

BEFORE USING

Pressure Relief Plates

Remove Cardboard Before

Using Appliance

TYPICAL INSTALLATION SEQUENCE

The typical sequence of installation is outlined

below. However, each installation is unique

and may result in variations to the steps

described.

See the page numbers references in the follow-

ing steps for detailed procedures.

Step 1. (Page 9) Construct the appliance

framing. Position the appliance within

the framing and secure with nailing

brackets.

Step 2. (Page 11) Route gas supply line to

appliance location.

Step 3. (Page 12) Install the vent system and

exterior termination.

Step 4. (Page 25) Field Wiring

Install the operating control switch (not

factory provided) and bring in electri-

cal service line for forced air-circulat-

ing blower (standard equipment).

Step 5. (Page 26) Make connection to gas

supply.

Step 6. (Page 27) Verify appliance opera-

tion.

Step 7. (Page 28) Install the logs, decorative

volcanic stone and glowing embers.

Step 8. (Page 30) Install glass door assem-

bly.

Step 9. (Page 30) Adjust burner primary air

shutter to achieve proper flame ap-

pearance.

Step 10. (Page 31) Install the hoods.

Step 11. (Page 32) Attach Safety in Operation

Warnings.

Note: Frame the opening to the exact dimensions

specified in the framing details of this manual.

Side

Framing

Unit Nailing Flange

(No clearance to

combustible

framing is required)

Left Side Front Corner of Fireplace Shown

(Right Side Requirements the Same)

Unit Being Secured By Its Nailing Flanges

To The Framing

Figure 11

Step 1. FRAMING

Frame these appliances as illustrated in Figures

12 and 13 on Pages 10 and 11 (Figure 13

applies to corner framing installations only).

All framing details must allow for a minimum

clearance to combustible framing members as

shown in Table 5 on Page 8.

If the appliance is to be elevated above floor

level, a solid continuous platform must be

constructed below the appliance.

Headers may be in direct contact with the

appliance top spacers but must not be sup-

ported by them or notched to fit around them.

All construction above the appliance must be

self-supporting. DO NOT use the appliance for

structural support.

The fireplace should be secured to the side framing

members using the unit's nailing flanges - one top

and bottom on each side of the fireplace front. See

Figure 11. Use 8d nails or their equivalent.

WARNING

Failure to position the parts in

accordance with these diagrams

or failure to use only parts specifi-

cally approved with this appliance

may result in property damage or

personal injury.

AVERTISSEMENT

Risque de dommages ou de

blessures si les pièces ne sont

pas installées conformément à

ces schémas et ou si des pièces

autres que celles spécifiquement

approuvées avec cet appareil sont

utilisées.

Advertising