6.2.4. Gas change and multiple breathing gas mixes
One of Suunto D6’s special features is the possibility to set an additional nitrox mix to
be used during a dive. This feature can be activated by setting the MIX2 to ON and
entering other parameters in the same way as with the primary gas. Mix 2 settings
are held until you change them (they will not return to default settings automatically).
A dive is always started with MIX1. During the dive, the Suunto D6 enables you change
to another enabled mix, which is within the set maximum oxygen partial pressure. The
tissue calculation during the dive is based on the mix you have selected.
The Suunto D6 allows gas changes to enabled gas mixes during the dive. Gas changes
are made by following the procedure below:

CHANGING GAS MIX. SCROLL

THROUGH ENABLED MIXES BY

PRESSING THE UP OR DOWN

BUTTONS. SELECT NEW MIX BY

PRESSING THE SELECT BUTTON.

NOTE

Mix number, O

2

%, and PO

2

for the mixes are shown when

scrolling. If the set PO

2

limit is exceeded , it will be shown with

the PO

2

value blinking. The dive computer does not allow you to

change to a gas whose set PO

2

is exceeded. In such a case, the

mix is shown but cannot be selected.

70