AN.No.G1216B1N000-3D0E

- 10 -

In order to read the content of the output register, the Chip Select must be selected, D/I must be 1,

and R/W must be 1. When executing the “Read” instruction, the contents of the output register

stored at that time are output during the time that “E” is 1. When “E” falls, display data of the

currently indicated address is written in the output register. After that, the address advances by

one.

The contents of the output register are rewritten by the Read instruction. The data is retained by the

address set or other instructions. Accordingly, when performing the address set, and next executing

the Read instruction, the data of the specified address is not output and the data of the address

which is specified is output at the second data read time. Therefore, when setting the address, a

dummy read is needed once. See Figure 4.

Busy
Check

Data Read
(dummy)

Address
Set
(Address
N)

N+1 address data

N+2

N

N+1

N address data

D / I

R/W

E

Address

Output Register

DB

0

to DB

7

Busy
Check

Busy
Check

Data Read
(N address
data)

Busy
Check

Data Read
(N+1 address
data)

(2)

Busy flag

The status when busy flag is “1” means that the module is operating internally. Instructions other than

he Status Read are not available at this time. The busy flag is output to DB

7

by the Status Read

instruction. Ensure that the busy flag is “0” before executing the instruction.

BUSY

E

T

BUSY

F



is frequency of



1

or



2

(1 / 2 the source oscillation frequency of HD61203): 215 kHz typ.

1

F

 

T

BUSY



3

F



(3)

Display ON/OFF Flip/Flop

The display ON/OFF Flip/Flop is a flip-flop function that determines whether the display data

corresponding to the RAM data is output to the segment on the LCD (ON status ) or goes to all nonlit

status regardless of the RAM data (OFF status). This is controlled by the display ON/OFF instruction.

When the RST signal becomes “0,” the display goes to OFF status. This flip-flop status is output to DB

5

by the Status Read instruction.

Even when performing display ON/OFF, the data inside the RAM is not affected.

Figure 4 Read Timing

Figure 5 Busy Flag

Advertising