Reset function – Seiko Instruments G1216B1N000-3D0E User Manual

Page 19

Advertising
background image

AN.No.G1216B1N000-3D0E

- 16 -

3.3 Reset Function

Setting the RST terminal to a low level when the power is on allows for initial setup.



Display OFF



Display start line register: Set address 0.

While the RST remains at a low level, instructions other than the status read cannot be accepted.

Execute other instructions after confirming that DB

4

=0 (reset release) and DB

7

=0 (ready) , using the

status read instruction.

The power conditions for power-on initial setup are as follows:.

Item

Reset time

Rise time

Symbol

t

RST

t

r

Min

1.0



Typ.





Max



200

unit



s

ns

t

RST

t

r

0.3V

DD

V

DD

RST

4.5V

0.7V

DD

If the RESET is executed during operation, retention of the contents of all registers (excluding an

ON/OFF register) and the RAM is not guaranteed. Always set them again.