Terminal functions – Seiko Instruments G1216B1N000-3D0E User Manual

Page 17

Advertising
background image

AN.No.G1216B1N000-3D0E

- 14 -

3. OPERATING INSTRUCTIONS

3.1 Terminal Functions

8

I/O

MPU

Common terminal for tristate input and output, and data bus.

Functions

Destination

I/O

QTY

Signal

DB

0

to

DB

7

E

1

Enable
Write (R/W=0):Latches data of DB

0

to DB

7

at the fall of E.

Read (R/W=1):Outputs data to DB

0

to DB

7

while “E” keeps a

high level.

Input

MPU

R/W

1

Input

MPU

Read/Write selection
R/W=1: When E=1 and CS1=0 or CS2=0, the data is output

to DB

0

to DB

7

and read is available by MPU.

R/W=0: When CS1=0 or CS2=0, DB

0

to DB

7

are ready for

receiving the input.

D/I

1

Input

MPU

Data/Instruction selection
D/I=1: Indicates that the data in DB

0

to DB

7

is the display

data.

D/I=0: Indicates that the data in DB

0

to DB

7

is the instruction

code.

CS1, CS2

2

Input

MPU

Chip select input. Data input and output is possible under

the following status:

Terminal No.

Status

RST

1

Input

MPU

Reset signal
Setting the RST signal to a low level allows for initial setup.

(1) ON /OFF register: 0 setup (display OFF)
(2) Display start line register: 0 line setup (display starts

from 0 line)

The setup status is retained until the status is changed by an

instruction after reset is released.

V

DD

1



Power

Power terminal for logic (+5 V)

V

SS

1



Power

GND terminal (0 V)

V

LC

1



Power

Power terminal for LC drive

LEDA

1



Power

LED backlight anode terminal

1

F

GND

terminal is connected to the metallic frame of the module. Use this terminal when

grounding the frame.

LEDC

1



Power

LED backlight cathode terminal

F

GND

1





Frame ground

1

CS2

CS1

LCM display screen

CS1

0

CS2

0

CS1: Controls the LCM left half display screen (SEG1 to

SEG64).

CS2: Controls the LCM right half display screen (SEG65 to

SEG128).

Table 1 Terminal Functions

Advertising