Part names and functions – Samsung SPD-1000 User Manual

Page 7

Advertising
background image

13

12

Camera Initial Settings

Setting Baud Rate Based on DVR Model

If the speed dome camera is controlled not by the camera controller but by a
DVR, set the communication speed based on the DVR model as follows.

Part Names and Functions

• Default Setting : Samsung 9,600 bps
• AD, Bosch is now preparing.

Notes

Setting Communications Protocol

Use the SW2 #1~#5 of installation bracket to set the communications protocol.

NO.

Protocol

Baud Rate(BPS)

SW2-#1

SW2-#2

SW2-#3

SW2-#4

SW2-#5

1

Samsung

9,600

OFF

OFF

OFF

OFF

OFF

2

Samsung

19,200

OFF

OFF

OFF

OFF

ON

3

Pelco-D

2,400

OFF

OFF

OFF

ON

OFF

4

Pelco-D

4,800

OFF

OFF

OFF

ON

ON

5

Samsung Elec.

9,600

OFF

OFF

ON

OFF

OFF

6

Samsung Elec.

19,200

OFF

OFF

ON

OFF

ON

7

Panasonic

9,600

OFF

OFF

ON

ON

OFF

8

Panasonic

19,200

OFF

OFF

ON

ON

ON

9

Vicon

4,800

OFF

ON

OFF

OFF

OFF

10

Vicon

9,600

OFF

ON

OFF

OFF

ON

11

AD

4,800

OFF

ON

OFF

ON

OFF

12

Bosch

9,600

OFF

ON

OFF

ON

ON

13

Bosch

19,200

OFF

ON

ON

OFF

OFF

14

Honeywell

9,600

OFF

ON

ON

OFF

ON

15

Honeywell

19,200

OFF

ON

ON

ON

OFF

16

Sungjin

4,800

OFF

ON

ON

ON

ON

17 32

Reserve

Setting Transmission Mode

Set the transmission mode using the ON/OFF of the Dip Switch 2.

Samsung

Pelco

Samsung Elec.

SVR-950

9600,19200

2400,4800

19,200

SVR-1640

9600,19200

2400,4800

19,200

SVR-1650

9600,19200

2400,4800

19,200

Protocol

DVR Model

Function

ON

OFF

SW2- #6

Transmission Mode

Full

Half

Selection

(DVR)

(SCC-3100A)

• Factory Setting: OFF

Notes

Advertising