6 -4

Fault Symptom Codes (FSCs)

SCSI FIFO Error

1003

D, G

The SCSI controller data FIFO should be
empty but still contains data bytes.

SCSI Gross Error

1004

C, D, G

The SCSI controller detected a gross
error condition - invalid SCSI bus phase
or DMA error.

Illegal SCSI Cnt Cmd

1005

C, D, G

Either an invalid command was sent to
the SCSI controller, or the controller was
not in the correct mode.

SCSI Invalid Element

1007

D, G

Internal SCSI task processing error -
invalid element type was detected.

SCSI Invalid Int.

1009

D, G

The SCSI controller posted an invalid
interrupt status.

Loader Not Ready

2004

C, G

Fail to fetch, stow, scan, move passthru,
Or when loader detects invalid command,
aborts command.

Door Open (status
only)

2009

F

Door is force opened or door sensor
failed.

Cart Inaccessible

200C

F

For an LTO, indicates the tape is not
ejected. Cartridge in drive is not
accessible from changer.

Drive In Error

200D

C, G

A general drive error detected by control
task.

No Magazine

200E

F

Cannot move, element not installed, from
changer.

Removal Prevented

200F

F

Receive medium prevent removal from
drive for a fetch.

Ctl. Firmware Error

2010

C, G

Internal inter task processing error.
Unexpected event. SMX send or receive
error.

Drive Time-out Error

2030

C, G

Can’t communicate with DLT drive.

Drive Code Update
Command Error

2080

C, G

Update code from SCSI or from TAPE
failed.

Move Command
Failure

2081

C, G

Move command from / to drive slot failed,
detected by control task.

Open Mail Slot Fault

2090

C, G

Door open sensor time-out detected when
open door.

Open Left Door Fault

2091

C, G

Door open sensor time-out detected when
open door.

Open Right Door Fault

2092

C, G

Door open sensor time-out detected when
open door.

Table 6-2. Fault Symptom Codes