0 operating instructions, 1 setting water temperature, Operating instructions – Sundance Spas CONSTANCE 6530-512X User Manual

Page 32: Setting water temperature

Advertising
background image

Page 28

ELITE SERIES

9.0 Operating Instructions

The spa control system has automatic functions that operate upon startup

and normal operation to protect the system. Upon power up, the readout

displays the following information:

1. Control panel displays current software release (e.g.

3.58).

2. Control panel displays “888” and all indicator LEDs are

lit, permitting visual inspection of all display segments

and indicator lights for proper operation.

3. After the initial start-up sequence ends, the actual

water temperature is displayed. If water temperature

at this time is less than the factory default temperature setting of 100°F

(38°C) and the spa is set to either of the standard filtration/heating

modes (page 33), the heater will turn on and run until the water tem-

perature rises to the factory setting, then turn off.

Note: It is common for the heater to turn on after the spa is first filled

because tap water is often very cold.

4. Approximately two minutes after power is applied to the spa, the first

filtration/heating cycle turns on pump 1. An automatic five minute

“blow-out” function also activates pump 2 for a period of five minutes

to flush all lines. Then, after five minutes, pump 2 turns off and pump 1

continues to operate for the duration of the cycle.

Note: This function only occurs during the first filtration/heating cycle each

day.

9.1

Setting Water Temperature

The spa’s thermostat provides optimum control of water tem-

perature. The temperature setpoint (set temperature) can be

adjusted from 65-104°F (18-40°C). To raise the set temperature, press

the

WARMER (

) button. To lower the set temperature, press the

COOLER (

) button. The first press of either button displays the set

temperature. To access the overtemp feature that allows the spa to reach

106°F (41°C) follow the steps below (Figure 1).

A. Press and hold the

WARMER (

) button

then;

B. Press and hold the

jETS 1 (

1

) button at

the same time for 2 seconds. You will see

the temperature rise to 106°F (41°C) on the LED display. To lower

the temperature, press the

COOLER (

) button.

C. When the overtemp has been activated, the white decimal point after

the last digit will flash on and off every second as an indicator for

being in the overtemp mode.

Note: Once the temperature goes below 104°F (40°C) and you would

like to raise the temperature to 106°F (41°C) again, you will have to

repeat the steps above.

1.
2.

3.

1

2

A

B

C

Figure 1

Advertising