Alarm – Samsung SHR-9716 User Manual

Page 29

Advertising
background image

05

S

YS

TE

M

S

ET

U

p

System Setup _

25

Alarm

This setup category covers sensor, camera, and alarm association settings. By associating a camera to a sensor, you

can confi gure how long the camera is going to record for when a sensor event is detected. In addition, by associating an

alarm output to a sensor, you can setup the alarm output to sound a warning signal when a sensor event is detected.

1 Setting

Channel: Select the sensor you wish to confi gure.

Name:Enter the name of the sensor.

Pre rec time: Select the time prior to a sensor event

that the camera should record.

Post rec time: Select the time after to a sensor

event that the camera should record.

Full Screen: Make the linked camera channels pop-

up full screen on the display screen

when a sensor event occurs.

Dwell Time: This option is used to defi ne for how long

subsequent sensor event signals are

ignored after an initial event signal. Enabling

this option instructs the system to ignore

all other event signals transmitted by the

sensor for the set amount of time following

the initial event signal. So once an event

signal is transmitted, the set discard time

must lapse before another event signal can

be recognized.

2 Linked pTZ

Camera: Select the PTZ camera channel you wish

to associate to the sensor.

Preset: Select the PTZ preset for when the sensor

event is detected.

Spot Full up: Select the camera channel to be

displayed full screen on the spot

monitor in a sensor alarm event.

Dwell Time: Set the time that the camera is

displayed on the spot monitor.

3 Type

Select the input type of the sensor.

Click the button to switch between the NC and

NO option.

: Normally open, but closes when an event is

detected (Normally Open).

: Normally closed, but opens when an event is

detected (Normally Close).

4 Alarm Out

Channel: Select an alarm (Alarm Out) to associate

to the sensor (Alarm In).

Name: Enter the name of the alarm.

Dwell Time: Set how many seconds the alarm will

be active on a sensor event.

Alarm Out Button: Select a sensor channel to

associate to the alarm.

: Indicates an associated sensor.
: Indicates a non-associated sensor.

3

1

2

4

SPR-9816-9716.indb 25

2008-07-03 오후 2:46:39

Advertising