connecting with other device

connecting with other device

connecting the rs-485 device

Connect the RS-485 device through the back port.

For example, you can connect and control the PTZ
camera which supports the RS-485
communication.

Transfer Type : You may select either Half Duplex or Full
Duplex as the data transfer type.
Baud Rate : Supported Baud rates are 600/1200/2400/
4800/9600/19200/38400.

Check if the RS-485 device is compatible with the
product first.
Pay attention not to change the polarity (+/-) of the
RS-485 device when connecting it.
Depending on camera’s type, connection polarity can be
different.
For further information, refer to the respective PTZ
Camera’s documentation.
Ex : DVR(TX+/-)  SCC-C6433,35(RX+/-)

DVR(TX+/-)  SCC-C6403,07(TX+/-)

M

`

~

~

M

`

`

`

`

PTZ device

Half Duplex Type

Data (–)

Data (+)

Full Duplex Type

Rx(+)

Rx(–)

Tx(–)

Tx(+)

Rear

Tx(–)

Tx(+)

Rx(–)

Rx(+)