Request sense - 03h, Request sense — 03h, Table 76: request sense — 03h – Silicon Image SiliconDrive SSD-P16G(I)-3100 User Manual

Page 100: Table 77: extended error codes

Advertising
background image

ATA C

OMMAND

B

LOCK

AND

S

ET

D

ESCRIPTION

SSD-P

XXX

(I)-3100 D

ATA

S

HEET

S

ILICON

S

YSTEMS

P

ROPRIETARY

This document and the information contained within it is confidential and proprietary to SiliconSystems, Inc.

All unauthorized use and/or reproduction is prohibited.

3100P-06DSR

P

AGE

90

F

EBRUARY

2, 2009

Request Sense — 03h
The Request Sense command identifies the extended error codes generated
by the preceding ATA command. The Request Sense command must be
issued immediately following the detection of an error via the Error register.

The extended error codes are defined in the following table.

Table 76: Request Sense — 03h

Register

D

7

D

6

D

5

D

4

D

3

D

2

D

1

D

0

Feature

X

Sector Count

X

Sector Number

X

Cylinder Low

X

Cylinder High

X

Drive Head

1

X

1

Drive

X

Command

03h

Table 77: Extended Error Codes

Extended Error Codes

Description

00h

No error detected

01h

Self test is OK (no error)

09h

Miscellaneous error

20h

Invalid command

21h

Invalid address (requested head or sector invalid)

2Fh

Address overflow (address too large)

35h, 36h

Supply or generated voltage out of tolerance

11h

Uncorrectable ECC error

18h

Corrected ECC error

05h, 30h-32h, 37h,3Eh

Self test of diagnostic failed

10h, 14h

ID not found

3Ah

Spare sectors exhausted

1Fh

Data transfer error/aborted command

0Ch, 38h, 3Bh, 3Ch, 3Fh Computed media format
03h

Write/erase failed

Advertising