Configuration and status register (202h), Table 23: configuration and status register (202h) – Silicon Image SiliconDrive SSD-P16G(I)-3100 User Manual

Page 48

Advertising
background image

A

TTRIBUTE

M

EMORY

D

ESCRIPTION

AND

O

PERATION

SSD-P

XXX

(I)-3100 D

ATA

S

HEET

S

ILICON

S

YSTEMS

P

ROPRIETARY

This document and the information contained within it is confidential and proprietary to SiliconSystems, Inc.

All unauthorized use and/or reproduction is prohibited.

3100P-06DSR

P

AGE

38

F

EBRUARY

2, 2009

C

ONFIGURATION

AND

S

TATUS

R

EGISTER

(202

H

)

The Configuration and Status Register (CSR) informs the host of any status
changes with regard to power-down.

Table 23: Configuration and Status Register (202h)

Operation

D

7

D

6

D

5

D

4

D

3

D

2

D

1

D

0

Read

Changed SigChg IOis8

0

0

PwrDn

Int

0

Write

Changed SigChg IOis8

0

0

PwrDn

Int

0

Default
Value

0

0

0

0

0

0

0

0

Bit(s)

Description

Changed

Indicates that either CREADY (D5) or CWPort (D4) of the Pin
Replacement register is set. Additionally, this bit changes state
as the Powerdown (D2) bit changes.

SigChg

Outputs the inverse state of the Changed bit to the hardware
interface signal STSCHG# at the card interface.

Iois8

Informs the host of the valid data bus width for the operations in
progress:

• 0 = 16-bit data transfer
• 1 = 8-bit data transfer

PwrDwn

Indicates the state of the Card, which is either operating -0 or
powerdown mode 1. During powerdown mode, no commands
are accepted. Additionally, the host may not initiate a
powerdown request when the card is busy via the Status
register or the Hardware RDY/BSY pin.

Int

Indicates the inverse of the IREQ# status signal.