Abridged Command List

A

Return the ‘REL’ Status

A0

Turn the ‘REL’ off

A1

Turn the ‘REL’ on

B

Return Bandpass Filter Status

B0

Take out the Bandpass Filter

B1

Put in the Bandpass Filter

C

Return the Reference LCD Status

C0

Display the Reference Frequency

C1

Display the Reference Phase Shift

D

Return Dynamic Reserve Setting

D0

Set DR to LOW range

D1

Set DR to NORM range

D2

Set DR to HIGH range

En

Return Expand Status

En,0

Turn Expand off

En,1

Turn Expand on

F

Return the Reference Frequency

G

Return the Sensitivity Setting

G1

Select 10 nV Full-Scale

...

(G1-G3 with SRS preamp only)

G24

Select 500 mV Full-Scale

H

Return Preamp Status (1=installed)

I

Return the Remote/Local Status

I0

Select Local: Front panel active

I1

Select Remote: Front panel inactive

I2

Select Remote with full lock-out

J

Set RS232 End-of-Record to <cr>

Jn,m,o,p

Set End-of-record to n,m,o,p

K1

Simulates Key-press of button #1

...

(see un-abridged command list)

K32

Simulates Key-press of button #32

L1

Return Status of Line Notch Filter

L1,0

Remove Line Notch Filter

L1,1

Insert Line Notch Filter

L2

Return Status of 2XLine Filter

L2,0

Remove 2XLine Notch Filter

L2,1

Insert 2XLine Notch Filter

M

Return the f/2f Status

M0

Set reference mode to f

M1

Set reference mode to 2f

N

Return the ENBW setting

N0

Select 1 Hz ENBW

N1

Select 10 Hz ENBW

O

Return Offset Status

O0

Turn off Offset

O1,v

Turn on Offset, v = offset

P

Return the Phase Setting

Pv

Set the Phase to v. Abs(v) < 999 deg

Q

Return the value shown on the Output
LCD

R

Return the trigger mode

R0

Set the trigger for rising edge

R1

Set the trigger for + zero crossing

R2

Set the trigger for falling edge

S

Return the display status

S0

Display X = AcosØ

S1

Display Offset setting

S2

Display Noise

T1

Return pre-filter setting

T1,1

Set the pre-filter TC to 1 mS

...
T1,11

Set the pre-filter TC to 100 S

T2

Return the post-filter setting

T2,0

Remove post filter

T2,1

Set the post filter TC to 0.1 S

T2,2

Set the post filter TC to 1.0 S

V

Return the value of the SRQ mask

Vn

Set the SRQ Mask to the value n
(See the Status Byte definition)

W

Return the RS232 wait interval

Wn

Set RS232 wait interval to nX4mS

Xn

Return the voltage at the rear panel
analog port n. (n from 1 to 6)

X5,v

Set analog port 5 to voltage v

X6,v

Set analog port 6 to voltage v

Y

Return the Status Byte value

Yn

Test bit n of the Status Byte

Z

Reset to default settings and cancel
all pending command

Advertising