Robertson AP45 Autopilot

Installation

Simrad Robertson AS

Egersund - Norway

confirmation in the display if the AP45 has a software revision earlier than
V1R3.

Carry out the calibration procedure, then steer the boat on a known heading or
bearing. Slightly turn the heading sensor until the correct heading readout is
displayed. Tighten the screws.

Note!

If you sail the boat more than 15-20° north or south of the latitude of your last

calibration, the calibration procedure should be repeated. Calibration data is

stored in the RFC35NS and will only be deleted when a new calibration is

performed.

When connecting fluxgate compasses other than Robertson types, the FI100-40
Fluxgate Interface must be connected between the compass and the control unit.

The interface unit is bulkhead (or table) mounted with two screws.

The fluxgate compass is connected to a terminal board in the FI100-40 according
to the diagram enclosed with the unit. FI100-40 is connected to J2 of the control
unit according to Fig. 5-8.

Fig. 5-8

AP45/FI100-40 Fluxgate Interface - Wiring

Alignment

FI100-40 Fluxgate
Interface